NOTE: Note orientation of the rewind starter before
removal. Rewind starter may be installed in the 2
o'clock, 8 o'clock, 10 o'clock, or 12 o'clock positions.
NOTE: While removal of the rewind starter is not
required for removal of the blower housing, it is
recommended for cleaning and inspection purposes.
35

Blower Housing

1. See Figure 36. Remove four hex flange screws (A)
to release blower housing (B) from crankcase and
engine base.
NOTE: Use the internal T25 TORX recess for best
results.
NOTE: Bottom screw to engine base on cylinder
head side also captures cylinder heat shield. Bottom
screw to engine base on crankcase side also
captures flywheel guard.
NOTE: If engine is equipped with electric start,
bottom screw on crankcase side is removed with
starter motor/regulator.
36

Low Oil Sensor Module (If Equipped)

NOTE: If engine is equipped with electric start, oil sensor
module is removed with starter motor/regulator.
1. See Figure 37. Disconnect one-place wire connector
(A) between oil sensor and oil sensor module.
2. Disconnect one-place wire connector (B) between oil
sensor module and armature.
3. Remove hex flange screw (C) to release oil sensor
module bracket from flywheel guard.
NOTE: For low oil sensor removal, see SECTION
6 - SERVICE ENGINE SUBASSEMBLIES,
CRANKCASE AND CRANKCASE COVER,
DISASSEMBLY.
37

Armature

1. See Figure 38. Loosen two hex flange screws (A)
and rotate flywheel to move magnet (B) away from
armature legs.
2. Remove hex flange screws to release armature from
crankcase.
3. See Figure 39. Release armature wire (C) from
clip (D) on flywheel guard and pull from between
ribs (E) at top of crankcase.