Chapter 8 Checking Connections; Turning On The Devices; Setting Up The Server To Recognize The Logical Units - Fujitsu ETERNUS AF Configuration Manual

Hide thumbs Also See for ETERNUS AF:
Table of Contents

Advertisement

Chapter 8
Checking Connections
8.1

Turning On the Devices

To turn on the connected devices, use the following procedure:
1
Turn on the Fibre Channel switch power (if used).
2
Check that the Ready LED (or equivalent) is lit on the Fibre Channel switch.
3
Turn on the ETERNUS AF/DX.
4
Check that the Ready LED is lit on the ETERNUS AF/DX.
5
Turn on the server.
8.2

Setting Up the Server to Recognize the Logical Units

Make the server recognize the logical units (LUN) set in the ETERNUS AF/DX storage systems.
1
Use the "ioscan" command to check which devices are connected.
Enter as follows for LegacyView (old format) results:
# ioscan -fn
Enter as follows for AgileView (HP-UX11iv3 and newer format) results:
# ioscan -fnN
Check that all connected devices are listed in the ioscan output and "CLAIMED" is displayed in "S/W
State".
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX
21
Copyright 2020 FUJITSU LIMITED
P3AM-3772-22ENZ0