Installation; Pre-Installation Instructions; Inverter Node Address Setting - Mitsubishi Electric FR-E5NP Instruction Manual

Transistorized inverter
Table of Contents

Advertisement

2.INSTALLATION

2.1 Pre-Installation Instructions

Make sure that the input power of the inverter is off.
With input power on, do not install or remove the option unit. Otherwise, the inverter and
option unit may be damaged.

2.2 Inverter Node Address Setting

Set the node address of the inverter on the Profibus network.
Set the inverter node address before switching on the inverter and do not change the setting while power is
on.
The node address may be set between 0
CAUTION
1. Do not set the node address to 7E
2. Depending on the master module, 0
3. The node address changed while powering on the inverter is not made valid. The station
number setting is made valid either after power is reapplied or when the RES signal turns on.
4. You cannot set the same node address to other devices on the network. (Such setting disables
normal communication.)
CAUTION
and 7D
.
H
H
through FF
.
H
H
, 1
, 2
, 7C
, 7D
may not be used.
H
H
H
H
H
4