Chassis Installation
14. Connect the appropriate data cables.
If you have a standard configuration, you are done with module installation.
If you have a segmented backplane configuration, proceed to the following
pages in this chapter:
Page 16 for procedures to install the AT-TS90TR or the AT-TS95TR
switch for a 7-slot segmented backplane configuration, or
Page 17 for procedures to install an external switch for either the 4- or
8-slot segmented backplane configuration

Installing the AT-TS90TR or AT-TS95TR Switch in the Chassis

This procedure applies only if you are installing an AT-TS90TR or AT-TS95TR
switch in a 7-slot, segmented backplane, rackmount or desktop chassis.
To install the AT-TS90TR or AT-TS95TR switch:
1. Remove the four screws and rubber feet from the bottom of the switch.
Refer to Figure 11 on page 14 for an example.
Do not re-install the screws on the switch after removing the rubber feet.
Save the screws and rubber feet for a standalone configuration at a later
date.
2. Remove the dust cover from the back of the switch module, if in place.
See Figure 12 on page 14 for an example.
3. Slide the switch along the chassis guides of slot 7 but do not push it all the
way in.
4. Power up the switch and check the front panel LEDs to ensure the switch
is operational.
5. Push gently to seat the switch's interrepeater bus connector into the
segmented backplane.
6. Pull the handles on the left and right side of each module to expose the
mounting brackets.
See Figure 13 on page 15 for an example.
7. Attach the mounting brackets of the switch module to the chassis frame
with the module screws provided.
16
Note