To change the voltage:
Setting the voltage too high will cause overheating of the fans in the
chassis. Setting the voltage too low will reduce the effectiveness of the fans
and will cause overheating of the modules.
1. Use the slotted end of a screwdriver to remove the fuse carrier.
2. Pull out the fuse board and turn upside down.
3. Re-insert the fuse board in the carrier until the required voltage appears in
the window as in Figure 8 on page 10.
4. Re-insert the carrier into the chassis.
You are done with voltage reconfiguration.

Installing the Chassis

Install your chassis as follows (choose one that applies):
Rackmount models in a 19-inch rack (page 12)
Horizontal desktop models (page 12)
Vertical 4-slot desktop models (beginning on page 12)
Do not expose the chassis to water or mist. Install the chassis in a dust-
free environment. Do not place desktop chassis on the floor. Install the
chassis properly to avoid exposing personnel to high voltage and other
risks. Modules must be installed by qualified personnel. See Electrical
Safety and Installation Requirements on page i.