Status messages
normal operation
Tab. 2:
Status messages
battery
Tab. 3:
Status messages
programming
mode
Functions and operation

Signals

The external door fitting contains a signal LED and a buzzer. The signals and their
meanings are explained in the following tables.
Normal operation
There is no fault present in the normal operating mode.
LED signal
green
red
red
red
red
red
10x
Battery change required
The battery is low or empty ("Replacing the battery", page 47).
5 s
LED signal
yellow 5 s
yellow
5 s
5 s
red
red
Programming mode
The ESA500 / ESA501 electronic door fitting is in programming mode.
LED signal
green
red
orange
Meaning
Door can be opened.
Door cannot be opened.
red
Door cannot be opened (permanently locked).
Cannot be locked again once released.
Meaning
yellow
Battery is very low.
Access is only granted after a waiting period of
15 seconds and once the door code has been
entered again. The waiting time is increased to
60 seconds after 100 on-site inspections.
red
Battery is empty.
The door fitting no longer grants access.
Buzzer
1x long
3x short
1x short
125 ms
Meaning
Input action required.
Input action not required.
Additional inputs required.
Touchtone keys: audible beep con-
firms the push of a button.