How To Connect Wiring To The Terminal - Sanyo C2432A Installation Instructions Manual

Hide thumbs Also See for C2432A:
Table of Contents

Advertisement

Loose wiring may cause the
terminal to overheat or result
in unit malfunction. A fire
hazard may also exist.
Therefore, ensure that all
wiring is tightly connected.
When connecting each power wire to the correspond-
ing terminal, follow the instructions on "How to connect
wiring to the terminal" and fasten the wire securely with
the fixing screw of the terminal plate.

7-5. How to Connect Wiring to the Terminal

For solid core wiring (or F-cable)
(1) Cut the wire end with a wire cutter or wire-cutting
pliers, then strip the insulation to expose the solid
wire about 1 in.. (Fig. 7-1)
(2) Using a screwdriver, remove the terminal
screw(s) on the terminal plate.
(3) Using the pliers, bend the solid wire to form a
loop suitable for the terminal screw.
(4) Shape the wire loop properly, position it on the
terminal plate and fix it securely with the terminal
screw using a screwdriver.
For stranded wiring
(1) Cut the wire end with a wire cutter or wire-cutting
pliers, then strip the insulation to expose the
stranded wiring about 3/8 in.. (Fig. 7-2)
(2) Using a Pillips head screwdriver, remove the
terminal screw(s) on the terminal plate.
(3) Using a ring connector fastener or pliers, securely
clamp each stripped wire end with a ring connec-
tor. (Fig. 7-2)
(4) Place the ring connector, and replace and tighten
the removed terminal screw using a screwdriver.
(Fig. 7-3)
Solid wire
Insulation
Fig. 7-1
Stranded wire
Fig. 7-2
Special
Screw
washer
Ring connector
Terminal plate
Wire
Fig. 7-3
40
S4179694
Loop
1004_M_I
Ring
pressure
terminal
1106_M_I
Screw and
Special washer
Ring
connector
Wire
0120_M_I

Hide quick links:

Advertisement

Table of Contents
loading