How To Connect Wiring To The Terminal - Sanyo PNR-XS2432 Installation Instructions Manual

Split system air conditioner
Table of Contents

Advertisement

Loose wiring may cause the
terminal to overheat or result
in unit malfunction. A fire
hazard may also exist.
Therefore, ensure that all
wiring is tightly connected.
When connecting each power wire to the correspond-
ing terminal, follow the instructions on "How to connect
wiring to the terminal" and fasten the wire securely with
the fixing screw of the terminal plate.

6-5. How to Connect Wiring to the Terminal

For solid core wiring (or F-cable)
(1) Cut the wire end with a wire cutter or wire-cutting
pliers, then strip the insulation to expose the solid
wire about 1 in.. (Fig. 6-3)
(2) Using a screwdriver, remove the terminal
screw(s) on the terminal plate.
(3) Using the pliers, bend the solid wire to form a
loop suitable for the terminal screw.
(4) Shape the wire loop properly, position it on the
terminal plate and fix it securely with the terminal
screw using a screwdriver.
For stranded wiring
(1) Cut the wire end with a wire cutter or wire-cutting
pliers, then strip the insulation to expose the
stranded wiring about 3/8 in.. (Fig. 6-4)
(2) Using a Pillips head screwdriver, remove the
terminal screw(s) on the terminal plate.
(3) Using a ring connector fastener or pliers, securely
clamp each stripped wire end with a ring pressure
terminal. (Fig. 6-4)
(4) Place the ring pressure terminal, and replace and
tighten the removed terminal screw using a
screwdriver. (Fig. 6-5)
Solid wire
Insulation
Stranded wire
Special
Screw
washer
Ring pressure
terminal
Terminal plate
Wire
20
S4359128
Loop
1004_M_I
Fig. 6-3
Ring
pressure
terminal
1106_M_I
Fig. 6-4
Screw and
Special washer
Ring
connector
Wire
Fig. 6-5
1308_M_I

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xs1852C1852Cl1852

Table of Contents