3.2

Storage Inverter

If the inverter is not used immediately, please keep the inverter in a specific environment according to the following:
Do not unpack the inverter and put desiccant in the original box if the PV inverter is unpacked.
Store temperature range : -25°C~+60°C;Relative humidity range : 0~100%.
When the inverter is placed multi-layered, it can be folded up to four layers.
Do not position the inverter at a front tilt, excessive back tilt, or side tilt, or upside down.
Ensure that qualified personnel inspect and test the inverter before use if it has been stored for a long time.

3.3 Identify Inverter

Inverter body label.The following is only for reference,specific please in kind prevail!
Product Name :
Product Model:
Max.Input Voltage:
Input Voltage Range :
Max.Input Current:
Input Short Circuit Current:
Rated Output Voltage :
Rated Output Frequency:
Max.Output Current :
Rated Output Power:
Max.Apparent Power:
Adjustable Power Factor Range:
Enclosure:
Temperature Range:
Protective Class:
12
Three phase Grid-tied PV String Inverter User Manual
Number Description
1
Product name and modle
1
2
Product technical parameters
3
SN Barcode
4
Approve and Safety identification
2
3
4
Three phase Grid-tied PV String Inverter User Manual
4.

Installation

After checking the outer packing, move the PV inverter to the designated installation position horizontally.
1. Please place the inverter level on foam, paper and ensure that the ports are
not stressed to avoid damage or scratches inverter.
CAUTION
2. The inverter is heavier, be careful to prevent the inverter from slipping
and hurting the operator when moving the inverter.
Ensure there is no electronical connections around ports of the PV inverter
DANGER
before installation.

4.1 Selecting the Mounting Location

4.1.1 Installation Environment Requirements
a. The storage inverter protection class is IP65 and can be mounted indoors or outdoors.
b. To ensure optimum operation and long service life, the ambient temperature must be below 50℃.
c. Do not install the inverter in a rest area since it will cause noise during operation.
d.The carrier where the inverter is mounted must be fire-proof. Do not mount the inverter on flammable
building materials.
e. To ensure that the installation wall is required to install the inverter
f . Product label and warning symbols shall be clear to read after installation.
g. The installation height should be reasonable and make sure it is easy to operate and view the display.
h. Please avoid direct sunlight, rain exposure, show lay up install.
No direct sunlight
No rain Exposesure
No snow lay up
Snow lay up
Direct Sunlight
Rain Exposure
Installation