MODEL
PV 5KTL-D3/G2
Input(PV)
Max. PV power voltage (V)
Rated input voltage (V)
Max. input current Imp(A)
15A/15A
Max. short-circuit current Isc(A)
20A/20A
Starting voltage/Min. operating voltage
MPPT operating voltage range
MPPT voltage range @full load (V)
170V-850V
Max. numbers of input strings
Numbers of MPPT input
Maximum Feedback Current(A)
Output(Grid)
Rated output power
5KW
Rated output apparent power
5KVA
Max. apparent power
5.5KVA
Max. active power
5.5KW
Max. output current
3*8.4A
Rated ouput current
3*7.6/7.2/6.9A
Inrush Current
40A
Maximum Output Overcurrent Protection
40A
Maximum Output Fault Current
60A
Rated ouput voltage (V)
AC voltage range
Rated grid frequency
Grid frequency range
THDI
Current DC off-sets
Adjustable power factor range
Protection
DC switch
Anti-islanding protection
AC Overcurrent protection
AC short circuit protection
DC reverse connection
Surge Arrester
Insulation impedance detection
Leakage current protection
General
Topology
Protection grade
Power consumption at night
Cooling type
Operating temperature range
Operating relative humidity range
Max. operation altitude
Noise emission
Dimensions (W*H*D)
Weight (kg)
Display & Communication
Display
Communication
Protective Class
class I
AC Overvoltage Category
Category III
Category Ⅱ
DC Overvoltage Category
Inverter Topology
Non-isolated
Grid Connection Standard
AS/NZS4777.2-2020 AS/NZS4777.2-2020 AS/NZS4777.2-2020 AS/NZS4777.2-2020
PV 6KTL-D3/G2
PV 8KTL-D3/G2
PV 10KTL-D3/G2
1100V
620V
15A/15A
15A/15A
15A/15A
20A/20A
20A/20A
20A/20A
180V/160V
160V-1000V
210V-850V
270V-850V
340V-850V
2(1/1)
2
0A
6KW
8KW
10KW
6KVA
8KVA
10KVA
6.6KVA
8.8KVA
11.2KVA
6.6KW
8.8KW
11.2KW
3*10.1A
3*13.4A
3*17A
3*9.1/8.7/8.3A
3*12.1/11.6/11.1A
3*15.2/14.5/13.9A
40A
40A
40A
40A
40A
40A
60A
60A
60A
380V/400V/415V 3W+N+PE
260V-510V(Adjustable)
50Hz/60Hz
45Hz-55Hz/55Hz-65Hz
<3% Rated power
<0.5%In or 50mA
>0.99@full load power (adjuestable 0.8LG-0.8LD)
Support
Active Frequency Drift
Support
Support
Support
DC Type II/III; AC Type II/III (Optional)
Support
Support
Support
IP66
<1W
5~15K(natural-cooling)/15~25K(air-cooling)
-25℃-60℃(Maximum 45℃ without derating)
0~100%
4000m
<30dB representative value (natural-cooling)
(398*460*190)mm
16.8
LED/LCD(Optional)
Bluetooth&WiFi,RS485/GPRS/4G(Optional)
class I
class I
class I
Category Ⅲ
Category Ⅲ
Category Ⅲ
Category Ⅱ
Category Ⅱ
Category Ⅱ
Non-isolated
Non-isolated
Non-isolated