  • Page 2: Preface

    Inverters must be installed by professional electrical engineers who have obtained relevant qualifications. Scope Natural cooling series Fan cooling series Fan cooling series PV 22KTL-D3/G2 PV 5KTL-D3/G2 PV 10KTL-D3/G2P PV 6KTL-D3/G2 PV 25KTL-D3/G2 PV 15KTL-D3/G2P PV 8KTL-D3/G2 PV 17KTL-D3/G2 PV 10KTL-D3/G2...
  • Page 3: Table Of Contents

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Contents Contents CONTENTS 6. Startup/Shutdown the System Preface 6.1 Check before startup/shutdown the system About This Manual Target Group 6.2 Startup/Shutdown steps Scope 6.3 Shutdown the system Conventions 7.
  • Page 4: Safety

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Safety Safety 1. Safety Before using the inverter, please read all instructions and cautionary markings on the unit and manual. Installation,maintenance and connection of inverters must be performed by qualified personnel, in Put the instructions where you can take them easily.
  • Page 5: Product Introduction

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Product Introduction Product Introduction 2. Product Introduction Product Appearance 2.1 Overview The following is only for reference,specific please in kind prevail. The three-phase grid-tied PV inverter converts the DC generated by PV panels into three-phase alternating current and is delivered to the grid.
  • Page 6: Upack And Storage

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Upack and Storage Product Introduction Upack and Storage 3.1 Upack and Check Complete test and strict inspection before the inverter is sent out. When receiving the inverter, check that the packing materials are intact. After unpacking, examine the PV inverter and its fittings for damage and check that the deliverables are complete.
  • Page 7: Storage Inverter

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Product Introduction Installation Installation Storage Inverter After checking the outer packing, move the PV inverter to the designated installation position horizontally. If the inverter is not used immediately, please keep the inverter in a specific environment according to the following: Do not unpack the inverter and put desiccant in the original box if the PV inverter is unpacked.
  • Page 8 Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Installation Installation 4.1.2 Mounting Requirements Installation perspective schematic Mount the inverter vertically or tilted backward by max 15°. In order to facilitate the heat dissipation of the inverter.
  • Page 9: Mounting

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Installation Installation 4.2 Mounting Step 1. Install the mounting bracket Step 2.Install the inverter. Install the inverter on the bracket accurately and tighten the screws at both sides , as shown in Figure 5 and 6.
  • Page 10: Electrical Connection

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Electricity Connection Electricity Connection Electrical Connection Grounding According to the EN50178 requirement, the right side of the device has a protective grounding connection. System Connection Be sure to connect this interface to the grounding line when installing the device.
  • Page 11: Ac Connection

    Unscrew the nut of the cover and thread the AC cable (5 wires) cross the nut、threaded sleeve and the PV 5KTL-D3/G2,PV 6KTL-D3/G2,PV 8KTL-D3/G2 the cover. Then crimp the OT terminal and use heat shrink tubing or insulation tape for protection.
  • Page 12: Dc Connection

    PV input configuration To ensure that the inverter reaches the enclosure of IP65, it can only NOTE PV 5KTL-D3/G2, PV 6KTL-D3/G2 PV strings circuit<15A, All PV strings are connected into a group use the connector provided by supply. PV 8KTL-D3/G2, PV 10KTL-D3/G2P PV strings circuit<12A,...
  • Page 13: Communication Connection

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Electricity Connection Electricity Connection 5.3.2 Connection 5.4.2 WIFI/GPRS Module Connection(Optional) WiFi/GPRS module connection please refer to below. PV connection please refer to below. For details about APP settings, see the WIFI/GPRS Module Installation Guide in the packing case. 8~10mm Positive Connector ×...
  • Page 14 Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Electricity Connection Electricity Connection ④ Go to Console>Communication Setting > RS485 Setting > Modbus Page,check the Modbus address(the default 2 × M4 screw; �.�N.m value is 1),and click to modify the address as required if necessary.
  • Page 15: Startup/Shutdown The System

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Starup/Shutdown the System Starup/Shutdown the System Startup/Shutdown the System Shutdown the system If need to shutdown inverter in the process of daily use,please following this steps: Check before startup/shutdown the system Check follwing this steps after installtion.
  • Page 16 Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual User Interface User Interface Table 7-1 LED status descriptions Meter LED status Descriptions LED status Descriptions Red led blink slowly 1times/s Output side fault Blue led blink Standby or startup state E-Today...
  • Page 17: Troubleshooting And Maintenance

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Troubleshooting and Maintenance Troubleshooting and Maintenance 1.If the alarm occurs accidentally, possibly the power grid is abnormal accidentally. No Troubleshooting and Maintenance extra action is needed. 2.
  • Page 18 Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Troubleshooting and Maintenance Troubleshooting and Maintenance C7-System type If the alarm occurs, the inverter can not work,pls. restart the inverter.If the alarm 1.If the alarm occurs accidentally, the inverter can generate power, which may cause the error continues,pls.contact customer service to report repair.
  • Page 19: Maintenance

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Troubleshooting and Maintenance Troubleshooting and Maintenance Fan Maintenance Remote If this phenomenon occurs occasionally, it will not be used for communication signals. The inverter external fan abnormal will cause the inverter can’t be cooled effectively,affect the efficiency monitoring data is If long time data is not updated, pls.contact customer service report repair.
  • Page 20: Appendix

    Troubleshooting and Maintenance Appendix Appendix Note: Technical Specifications When uninstalling DC input connectors, insert removal wrench into the bayonet MODEL PV 5KTL-D3/G2 PV 6KTL-D3/G2 PV 8KTL-D3/G2 PV 10KTL-D3/G2 Input(PV) shown in Figure, press the wrench down, and take out the connector. 1100V Max.
  • Page 21 Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Appendix Appendix MODEL PV 15KTL-D3/G2P PV 17KTL-D3/G2 PV 20KTL-D3/G2 MODEL PV 10KTL-D3/G2P PV 12KTL-D3/G2 PV 15KTL-D3/G2 Input(PV) Input(PV) 1100V Max. PV power voltage (V) 1100V Max.
  • Page 22: Quality Assurance

    Three phase Grid-tied PV String Inverter User Manual Three phase Grid-tied PV String Inverter User Manual Appendix Appendix Quality Assurance MODEL PV 22KTL-D3/G2 PV 25KTL-D3/G2 Input(PV) 1100V Max. PV power voltage (V) Quality Terms 620V Rated input voltage (V) As for the PV inverter which is defective or damaged within its quality warranty period, Max.

Table of Contents