Unit Power
Requirements
Temperature •
NOTE
Memory •
Magnetic Stripe
Card
This chapter discusses power requirements, dimensions, and other specifications
of the UX301 card reader.
Operation voltage: 8 to 43V DC, 24V DC for Printer use
Idle Power: 2W
Typical Power: 3W (CTLS read), 4W (UX100 display heater), 0.5W (UX100/
110), 5W (RS232-vout)
Sleep Mode: TBD.
Operating temperature:
-30°C to 70°C (-22°F to 158°F) Standard unit
Storage temperature: -25°C to 70°C (-13°F to 158°F)
Power Supply rated for indoor use only: 12V DC 3.3A, operating temperature
0°C to 40°C (32°F to 104°F)
Power Supply rated for outdoor use: 24V, DC 3.75A up to 40°C (DC 2.5A up to
60°C), operating temperature -25°C to 60°C
Relative humidity: 5% to 90% RH non-condensing
If this device is to be used in the Nordic countries, or in any environment where
the temperature range exceeds the product's operating temperature, it is the
responsibility of the integrators to ensure that the ambient environment is
controlled in such a way to ensure that the product operates within the specified
temperature range.
External Dimensions
Height: 67 mm (2.64 in)
Width: 97 mm (3.82 in)
Depth 102 mm (4.02 in)
128 MB DDRAM