HP ProLiant DL345 Gen10 Plus Maintenance And Service Manual page 171

Table of Contents

Advertisement

Item
Item
Description
Description
1
2
Health LED
3
NIC status LED
4
UID button/LED
1
When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see
Front panel LED power fault codes
.
2
Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the
front I/O cable is disconnected.
3
If the health LED indicates a degraded or critical state, review the system Integrated Management Log (IML) or use
HPE
iLO to review the system health status.
Status
Status
Solid green
Flashing green
Flashing amber
Flashing red
1
Solid green
Flashing green
Off
1
Solid blue
Flashing blue
Off
Definition
Definition
Normal
iLO is rebooting
3
System degraded
3
System critical
Linked to network
Network active
No network activity
Activated
1 flash per second = Remote management
or firmware upgrade in progress
4 flashes per second = iLO manual reboot
sequence initiated
8 flashes per second = iLO manual reboot
sequence in progress
Deactivated
Front panel LEDs and buttons