37 Troubleshooting
Figure 124
Installer mode for
Installer mode
reset
By pressing the "
" push button for 20 seconds, it is possible to entered the Installer mode. During this time, the OTC mode
must not be entered. The display starts showing: "tS" flashing. By means of the CH+ and CH- push buttons it is possible to select
"tS" or "In" or "Hi" or "rE". "tS" means "Transparent parameter"; "In" means "Inquiry"; "Hi" means "History"; "rE" means "
tS
Transparent parameter mode
In
Inquiry mode
Hi
History mode
rE
Reset all the History information
reset
By means of the "
" button (1 activation for 1 second) on "tS" it is possible to enter the "Transparent parameter" mode, on "In"
it is possible to enter the "Inquiry" mode, on "Hi" is possible to enter the "History" mode; by means of the "eco" button (1 activa-
tion for 3 seconds) on "rE" is possible to reset all the History information.
reset
By pressing the "
" button for 20 seconds, it is possible to leave the Installer mode. If no action has been taken, the control
automatically leaves this mode after 2 minutes.
"tS" as Transparent Parameters mode (TSP)
Selecting "tS" the display starts with showing "P01" blinking. By means of the CH+ and CH- push buttons it is possible to select
the parameters; between "P01" and "P34". Selecting one of these parameters, by means of the DHW+ and DHW- push buttons is
possible to adjust his value (not flashing). To save, press the DHW- and DHW+ push buttons together.
The default "tS"settings for the boiler have been set by the Manufacturer and there should be no need to change.
Figure 125
"tS" - Transparent Parameter mode for
Parameter Description
P01
Ignition level (%)
P02
CH slope control (°F/min)
P03
Minimum Virtual set point (°F)
P04
CH OFF time (Min)
P05
CH pump over-run time (Min)
P06
CH pump selection (0-7)
P07
CH modulating pump PWM absolute min (%)
P08
CH modulating pump PWM start (%)
P09
CH modulating pump PWM absolute max (%)
P10
CH supply for CH pump over-run OFF (°F) - DHW config. 2
CH supply for CH pump over-run OFF (°F) - DHW config. 3
P11
CH supply for CH pump over-run ON (°F) - DHW config. 2
CH supply for CH pump over-run ON (°F) - DHW config. 3
P12
CH set point limit HIGH (°F)
P13
CH maximum output (%)
Part number 550-142-950/0122
-
wall mount gas
fired water boiler
(continued)
FreeStyle
®
boilers
FreeStyle
boiler manual
blinking
See Figure 125 thru 128, pages 99-101.
blinking
See Figure 129 & 130, pages 101-102.
blinking
See Figure 131, page 102.
blinking
®
boilers
Default
60 or 80
or 50
6
95
2
15
0
30
75
100
68
91
9
18
190
100
reset
Notes
60% - FS-120 / 80% - FS-80
50% - FS-155
Do Not Adjust
Do Not Adjust
Do Not Adjust
Do Not Adjust
Do Not Adjust
DHW conf. dependent
Config. 2, Heating Only = 68
Config. 3, Combi = 91
DHW conf. dependent
Config. 2, Heating Only = 9
Config. 3, Combi = 18
Also in Test Mode
".