Freestyle 2 Series Manual page 103

Table of Contents

Advertisement

FreeStyle
®
2
series
37 Troubleshooting
Figure 132
Troubleshooting suggestions for
System Parameters list (default settings)
There are 4 basic configurations within the DHW mode, selected by parameter DHW configuration (see Parameters list, Num. 1).
Default value is model dependent. (2 for Heating Only models, 3 for Combi models). By changing the DHW configuration num-
ber (See Parameter "b02", Figure 123, page 98), all the data will be automatically set at default condition. Parameters that will be
changed according to the DHW mode are numbered from 9 to 46 (see Parameters list). All the parameters can be accessed with
a communication package running on the PC. Some parameters are available by the installer in the "ts", Transparent Parameter
mode through the control interface.
Table 5
FreeStyle
®
list of System parameters (default settings)
Category
Num. Address
Description
DHW boiler type
1
System
2
End user setting
3
End user setting
4
End user setting
5
End user setting
6
Exhaust protection
7
Firmware version
8
Part number 550-142-950/0122
-
wall mount gas
fired water boiler
(continued)
FreeStyle
E2 prom parameters
Description
CL5 – 05C8
DHW configuration
ML – 80D0
First start-up flag
ML – 80E2
Summer / Winter selection
ML – 80E3
Economy / Comfort selection
CL5 – 0A9D
CH set point limit - HIGH
CL5 – 056D
CH user set point
CL5 – 050B
Maximum exhaust gases temperature
ML – 80E8
Firmware version
boiler manual
®
boilers — Fault displays and diagnostics
(continued)
Unit
Range
Low
High
Value
Num
1
4
Num
0
1
Num
0
1
Num
0
1
°F
68
194
°F
68
194
°F
32
255
Num
0
99
Def
3
0
1
0
190
158
185
04
103