Freestyle 2 Series Manual page 107

Table of Contents

Advertisement

FreeStyle
®
2
series
37 Troubleshooting
Figure 136
Troubleshooting suggestions for
Category
Description
Num.
Dom. Hot Water
61
Dom. Hot Water
62
Dom. Hot Water
63
Dom. Hot Water
64
Dom. Hot Water
65
Dom. Hot Water
66
Dom. Hot Water
67
Dom. Hot Water
68
System
69
System
70
System
71
System
72
System
73
System
74
System
75
System
76
System
77
System
78
System
79
System
80
System
81
System
82
System
83
System
84
Delta T protection
85
Delta T protection
86
Delta T protection
87
Delta T protection
88
Delta T protection
89
Delta T protection
90
Delta T protection
91
Delta T protection
92
Delta T protection
93
Delta T protection
94
Delta T protection
95
Delta T protection
96
97
98
Part number 550-142-950/0122
-
wall mount gas
fired water boiler
(continued)
FreeStyle
E2 prom parameters
Address
Description
CL5 – 06F8
DHW maximum output
Free - TBD
ML – 80D9
DHW flow sensor type
CL5 – 127A
Flow sensor ON
CL5 – 1285
Flow sensor OFF
ML – 80DE
DHW flow sensor filter
ML – 811F
DHW Off mode
ML – 813C
Hours of no DHW flow to set the Economy mode
ML – 8122
Variable input switch functionality
ML – 8123
Gas type selection
CL5 – 121C
Fan speed in Stand-by mode
CL5 – 0934
Water pressure low limit
CL5 – 0A38
Water pressure nominal
CL5 – 2EDF
Water pressure high limit
ML – 8128
Water filling mode
ML – 811B
Main supply frequency
ML – 80DC
Variable output relay functionality
ML – 812A
External pcb variable output relay functionality
ML – 812B
CH supply2 over-temp_burnerOFF
ML – 812C
CH supply2 over-temp_burnerON
ML – 812D
Water pressure protection
ML – 813B
Post-Ventilation time
ML – 813D
Fault F20 function
ML – 80E0
3-way motor valve commutation timer
ML – 812E
CH modulating pump PWM absolute min
ML – 812F
CH modulating pump PWM start
CL5 - 0C64
CH modulating pump PWM absolute max
constant
CH Time loop
constant
DHW Time loop
constant
CH modulating pump PWM_decrease step
constant
CH modulating pump PWM_update_time
constant
Virtual set point_decrease step
constant
Virtual set point_decrease time
constant
DHW Virtual set point_decrease time2
constant
DHW Virtual set point_decrease time1
constant
DHW Virtual set point_increase time
Free - TBD
Free - TBD
boiler manual
®
boilers — Fault displays and diagnostics
(continued)
Unit
Range
Low
High
%
0
100
Num
0
1
10*l/min
0
100
10*l/min
0
100
Sec
0
10
Num
0
4
Hours
0
24
Num
0
4
Num
0
1
Hz
0
70
psi
0
12
psi
7
29
psi
36
50
Num
0
1
Num
0
1
Num
0
8
Num
0
8
°F
194
230
°F
194
230
Num
0
1
Sec
0
255
Num
0
1
Sec
4
10
%
0
100
%
0
100
%
0
100
Sec
Sec
%
Sec
°F
Sec
Sec
Sec
Sec
Def
Value
100
0
15
10
0
0
24
4
0
0
6
10
41
0
1
0
7
230
226
0
27
0
4
30
75
100
2
2
1
4
4
10
12
18
18
107