Freestyle 2 Series Manual page 110

Table of Contents

Advertisement

FreeStyle
®
2
series
37 Troubleshooting
Figure 139
Troubleshooting suggestions for
Some informations can be accessed with a communication package running on the PC.
Category
Description
Num. Address
Boiler
1
Boiler
2
Boiler
3
Boiler
4
Boiler
5
Boiler
6
Boiler
7
Boiler
8
Boiler
9
Boiler
10
Boiler
11
Boiler
12
Boiler
13
Boiler
14
Boiler
15
Boiler
16
Boiler
17
OpenTherm
18
OpenTherm
19
OpenTherm
20
• D1....the boiler is / has finished the call for Domestic Water heating, and is in the transition to either standby mode or
central heating mode.
• D2....the boiler has reached the required water set point, and the firing has stopped / with a call for Central Heating still
applied by the T-Stat to the boiler. Pumps will continue to operate and the boiler is monitoring the two internal water sen-
sors (return & discharge) waiting for a water "Delta-T" to return...at that time the boiler will re-fire if need be
• D3....the boiler has made 3 tries for ignition and has failed to ignite. A re-trial ignition cycle / delay is in effect for 3 more
tries to ignite.
Parameter Description
D1
After cycle of Domestic water mode, D1 will be displayed.
D2
When required boiler water set - point is reached D2 will be displayed.
D3
After an attempt for ignition, re-trial ignition delay is in effect (D3 is displayed).
* Check for proper fuel supply.
* Remove and check ignitor for proper gap, 5/32", replace if disfigured, check combustion setting Natural gas or LP.
* Insure condensate is draining properly.
* Insure venting size and length are correct and unobstructed.
110
-
wall mount gas
fired water boiler
(continued)
FreeStyle
Description
CL4 – A532
CH supply sensor1 temperature
CL4 – A567
CH supply sensor2 temperature
CL4 – A55B
CH return sensor temperature
CL4 -A53D
DHW sensor temperature
CL4 -A568
Exhaust sensor temperature
CL4 -1110
Water pressure sensor
CL4 -A554
Outside temperature sensor
CL4 -0FAB MSB
Control water set point
CL4 -FC02 MSB
CH Virtual set point
CL4 -FC02 LSB
DHW Virtual set point
CL4 – 11DC MSB
Fan speed -Setpoint
CL4 – 11DC LSB
Fan speed -Feedback
CL4 – 0364
Flame current
CL4 – FAFB MSB
PWM modulating pump
CL4 – FAFB LSB
Step of Triac modulating pump
CL4 – 0F0E
DHW flow sensor
ML -F68B
DHW over-temp_burnerOFF-initially_Temperature
CL4 – FAF4 MSB
OT room setpoint
CL4 – FAF4 LSB
OT room setpoint
CL4 – FAC8 MSB
OT room temp
®
boilers — Fault displays and diagnostics
E2 prom parameters
boiler manual
(continued)
Part number 550-142-950/0122
Unit
°F *10
°F *10
°F *10
°F *10
°F *10
Psi *10
°F *10
°F
°F
°F
Hz
Hz
uA *10
%
Num
Hz
°F
°F Int
°F Dec
°F Int