Freestyle 2 Series Manual page 112

Table of Contents

Advertisement

FreeStyle
®
2
series
38 Maintenance
Figure 142
Removal of Ignition electrode
2. Remove two (2) Phillips head screws securing the ignition
electrode to the boiler heat exchanger.
3. Carefully slide the igniter out of its mounting slot.
Use care when removing and handling igniter.
Igniter is very brittle and can break if not handled
carefully.
4. Remove and inspect the ignitor gasket. Replace with new if
necessary.
5. Inspect the ignitor ceramic and electrodes, 5/32" gap and not
bent or disfigured/warped.
6. Remove any white oxides accumulated on the ignition elec-
trode using steel wool. If the ignition electrode cannot be
cleaned satisfactorily, replace ignitor. If the igniter ceramic
is cracked or damaged, replace.
7. Reinstall ignition electrode, making sure gasket is in good
condition and correctly positioned.
TORQUE LIMIT
ening the two (2) ignition electrode retainer screws.
DO NOT exceed 20 inch-pounds.
8. Re-attach the ground wire to the electrode assembly.
9. Re-connect ignition wire in the back of control module.
Figure 143
Ignition electrode grounding
112
-
wall mount gas
fired water boiler
(continued)
— Use a torque wrench when tight-
boiler manual
Figure 144
Boiler front panel removed
(Combi 80/120 shown)
Inspect and clean the burner
Wait until heat exchanger/boiler is cooled down
before proceeding. Failure to do so can cause
severe injury.
1.
See Figure 144 and Figure 149, page 114, for removing
heat exchanger cover plate to access burner.
2.
Use a 10mm wrench or socket to remove the five (5) nuts
that secure the heat exchanger cover plate to the heat
exchanger.
3.
Remove the heat exchanger cover plate and the gasket.
Figure 145
Heat exchanger cover plate removed
Part number 550-142-950/0122

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Freestyle 2 Series

This manual is also suitable for:

Fs-80 ngFs-80 lpFs-120 ngFs-120 lpFs-155 ngFs-155 lp

Table of Contents