XPower X-200AT Series Maintenance Manual page 35

Air mover
Table of Contents

Advertisement

3. Steps of Disassembling
3.1 Unplug Air Mover (Fig. 5-1)
Turn on the switch to speed 3 to release the electricity of capacitor for 2 minutes, until the voltage
reduces to safe voltage. (Fig. 5-2) (Note: if there is something wrong with voltage, the electricity of
capacitor cannot release normally. Do not touch the live part directly without insulation tools).
Fig. 5-1
3.2 Use a flat-head screwdriver to pry out the four screw plugs near the handle. (Fig. 6)
3.3 Remove the screws on the housing. (Fig. 7)
Fig. 6
3.4 Remove kick stand. (Fig. 8)
3.5 Remove right housing. (Fig. 9)
Fig. 8
Screw
Plug
Fig. 7
Fig. 9
Fig. 5-2
Speed Switch