7.Methods For Malfunction - XPower X-200AT Series Maintenance Manual

Air mover
Table of Contents

Advertisement

Socket Lead Wire 3
(Black)
Power Line of L
(Black)
Power Line of N
(White)
Socket Lead Wire 2
(Blue)
6.6 Install Right Housing and screws. (Fig. 23)
6.7 Install Kick Stand. (Fig. 24)
Fig. 23
7. Methods for Malfunction
Malfunction 1 - The machine does not turn on.
(1) Check that the power supply is working, that there is good connection, and that the speed switch is
set to speed 1, 2, or 3 while the timer knob is pointing to ON or is greater than 0 (pointing to 0 is not
energized). If machine still does not turn on, proceed to method (2).
(2) Follow 3.1-3.5 to open the Air Mover. Check for loose terminal connections. (Fig. 21 and Fig. 22)
Tighten if necessary. If machine still does not turn on, proceed to method (3).
(3) Follow 4.1 to disassemble. Remove three wires connected to Speed Switch. Use the Multimeter
(diode position, Fig. 25) to check conduction of Speed Switch at each speed level:
Adjust to speed 1, use the Multimeter to check the switch (Fig. 26);
Adjust to speed 2, use the Multimeter to check the switch (Fig. 27);
Adjust to speed 3, use the Multimeter to check the switch (Fig. 28);
If there is a speed that does not function properly, follow steps 4.1-4.3 to replace Speed Switch
Fig. 22-B
X-200AT * /P-200AT *, X-230AT * /P-230AT *
Fig. 24
Motor Wire (White)
Timer Lead Wire
(Red)
Socket Lead Wire 1
(Red)