2.2.4

Fastening Cable Head

1. Use the screwdriber provided for tightening screws.
2. The tightening torque must be 0.054 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be
caused by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
Fasten the user system interface cable head to the IC socket for an FP-128 package on the user system
with the four screws (M2
alternating between screws on opposing corners. Take special care, such as manually securing the IC
socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the
screws or twisting the components.
8
CAUTION
10 mm) provided. Each screw should be tightened a little at a time,