Commissioning, Inspection and Maintenance

Setting the Date

Setting the Time

Configuring the Supply System/Charging Scheme

62
Vitoligno 300-C Installation/Service
Press the following keys:
1.
for the required date.
|/~
2. d to confirm.
Press the following keys:
1.
for the required time.
|/~
2. d to confirm.
The supply system is set at the factory for discharge
from a pellet silo with a vacuum supply system (setting "1")
Press the following keys:
1.
for the required supply system "1", "2", "5" or
|/~
"7". (For other supply systems, see page 79)
2. d to confirm.
When configuring the supply system, the following are
available for selection:
Setting "1" (factory set condition) for pellet supply via
vacuum supply system from a pellet silo and for discharge
with manual changeover unit from a pellet storage
room or pellet box.
Setting "2" for pellet supply via screw conveyor discharge
from the pellet storage room and onward transportation
via a vacuum supply system.