Download Print this page

Monte Carlo Fan Company Edge Coastal 60 Manual page 5

Edge outdoor ceiling fan

Advertisement

SAFETY CABLE INSTALLATION
13
Lag screw
Safety cable
Washer
Lock washer
• For Canadian installation and for USA
fan and light kit combinations over 35
lbs, in both flush and downrod modes the
safety cable must be installed into the
house structure beams using 3" lag
screws, washers and lock washers
provided.
• Make sure that when the safety cable is
fully extended, the lead wires are longer
than the cable and no stress is placed on
the lead wires.
• Note
If installing the secondary
:
support safety cable in the U.S., do not
remove knockouts in the outlet box.
15
Canopy bottom
cap
• Partially loosen one and remove one
preassembled screw from mounting
bracket. Save screw.
• Lift canopy up, aligning its keyhole slot
with the preassembled screw on
mounting bracket and twist clockwise to
lock in place. Reinstall the other screw
and tighten all screws securely.
• Attach canopy bottom cap onto canopy
by aligning its holes with the screws on
mounting bracket and fix it with the
magnet which is embedded in the cap.
14
Wall switch Black
Power source
White
Ground/Green
Ground/Green
Make wiring connections using wire connectors provided as indicated above.
Brown wire from fan to Brown wire from receiver marked Motor U.
Gray wire from fan to Gray wire from receiver marked Motor V.
Blue wire from fan to Blue wire from receiver marked Motor W.
White (Neutral) wire from house to White wire from remote marked AC IN N.
Black (Live) wire from house to Black wire from remote marked AC IN L.
Connect all green grounded wires to Grounded wire from House.
Make sure that no filaments are outside of the wire connectors.
Insert the remote receiver into mounting bracket.
After making the wire connections, the wires should be spread apart with the grounded
conductor and the equipment-grounding conductor on one side of the outlet box and
ungrounded conductor on the other side of the outlet box. The splices after being made
should be turned upward and pushed carefully up into the outlet box.
• Caution: The installation has to be complete before operate the fan. The receiver
has to be used on the fan and cannot be bypassed.
Page 5 of 8
Edge Outdoor Ceiling Fan
Brown Grey
Blue
Receiver
Black
White

Advertisement