LED STATUS AND TROUBLESHOOTING

The ignition control has a multi-colored (GREEN, ORANGE, and RED)
LED which will flash different colors and codes to show status of the
ignition and will help troubleshoot the control
Table 3: GREEN LED Indications of Normal Operation
Flash
1 flash every 1 sec.
Rapid flashing
Solid on
Table 4: ORANGE LED Indications
Flash
1 flash every 5 sec.
1 flash every 1 sec.
Table 5: RED LED Indications of ERROR Codes (100% Lockout)
Flash
1 flash
2 flashes
3 flashes
7 flashes
8 or 9 flashes
Solid on
Note: There is a one-second pause after each flash code.
Warning: Do not install the control in areas that can be exposed to dripping water,
steam cleaning, heavy dust, grease, or corrosive chemicals. If the controls can be
subjected to this type of environment, use a NEMA 4 rated enclosure to protect the
ignition control module.
If not properly protected from the above environment, the control will prematurely fail or
malfunction. Excessive high temperatures can damage the ignition control and cause
it to malfunction. Make sure the ambient temperature around the ignition does not
exceed the rated temperature for the control.
©
2019 BASO Gas Products
Part No. BASO-INS-C107UQRG, Rev. C
Indication
Pre-purge, Inter-purge
Trial for Ignition (TFI)
RUN (Flame, Main valve on)
Indication
Retry
Flame Present
Indication
No flame in trial time
Flame sense stuck
Valve relay circuit
Repetitive flame loss
Internal control
Line voltage/Frequency
24 VAC Universa Direct Spark Gas Ignition Control
.
Error Type
Standby
Standby
Error Type
100% Lockout
100% Lockout
100% Lockout
100% Lockout
100% Lockout
Standby
6
www.baso.com