SETUP AND ADJUSTMENTS

DIP Switch (S1) Settings
When replacing an existing ignition control with the C107U, refer to Table
2 for the correct DIP switch settings. For a complete list of the controls the
C107U replaces, see the BASO C107U Installation Instructions available
at www.baso.com.
The following timing parameters may be set with the 5-postion DIP switch
(see Table 2).
IMPORTANT:
The control timing configuration is permanently locked and cannot be reset
by changing the DIP switch settings after 10 consecutive power cycles.
FACTORY DEFAULT S1 DIP SWITCH SETTING
TIMING CONFIGURATION LABEL
Note: After the configured number
of trials for ignition with no established flame or the pre-defined number of
flame losses have occurred, controls with a retry time of 0 (i.e. none) will
enter a 100% Lockout mode, requiring the pre-defined lockout recovery
method (power cycle) to continue normal operation. However, controls
with a retry time of 5 or 60 minutes will enter a standby lockout mode for
the configured time before continuing to normal operation.
©
2019 BASO Gas Products
Part No. BASO-INS-C107UQRG, Rev. C
All switch settings are defaulted from the
factory to the "ON' position. Refer to Table 2
for the desired timing configuration. The
default timings are printed on the label
located on the front of the ignition.
24 VAC Universa Direct Spark Gas Ignition Control
Once you have selected the desired timing
configuration, using a permanent marker,
write in the values and mark the DIP switch
settings on the label provided. Adhere the
label to the front of the control for future
reference.