4 Installation
138mm (5.45in)
138mm (5.45in)
Left rear wall hole
Left rear wall
65mm (2.5in)
hole 65mm (2.5in)
34mm (1.35in)
34mm (1.35in)
965mm (38in)
965mm (38in)
Model C
Model C
221mm (8.7in)
221mm (8.7in)
79mm(3.1in)
54mm
54mm
79mm (3.1in)
(2.1in)
(2.1in)
Left rear wall hole
Left rear wall
138mm (5.4in)
138mm (5.4in)
65mm (2.5in)
hole 65mm (2.5in)
1080mm (42.5in)
1080mm (42.5in)
Model D
Model D
389mm (15.3in)
389mm (15.3in)
172mm (6.8in)
172mm (6.8in)
52mm (2.05in)
52mm (2.05in)
Left rear wall hole
Left rear wall
90mm (3.54in)
hole 90mm (3.54in)
1259mm (49.55 in)
1259mm (49.55in)
Model E
C
When the gas side connective
pipe is 16mm(5/8in) or more,
the wall hole should be 90mm
(3.54in).
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating
sleeve attached to the back of the unit. You must
prepare the piping before passing it through the
hole in the wall.
1. Based on the position of the wall hole relative to
the mounting plate, choose the side from which
the piping will exit the unit.
2. If the wall hole is behind the unit, keep the
knock-out panel in place. If the wall hole is to
the side of the indoor unit, remove the plastic
knock-out panel from that side of the unit. This
will create a slot through which your piping can
24 / 120 EN
517.4mm (20.37in)
517.4mm (20.37in)
144mm (5.65in)
144mm (5.65in)
Indoor unit outline
Indoor unit outline
Right rear wall hole
Right rear wall
65mm (2.5in)
hole 65mm (2.5in)
578mm (22.8in)
578mm (22.8in)
298mm (11.7in)
298mm (11.7in)
54mm (2.1in)
54mm (2.1in)
Indoor unit outline
Indoor unit outline
149mm
149mm
(5.9in)
(5.9in)
49mm (1.9in)
49mm (1.9in)
Right rear wall hole
Right rear wall
65mm (2.5in)
149mm (5.9in)
149mm (5.9in)
hole 65mm (2.5in)
643.6mm (25.3in)
643.6mm (25.3in)
257mm (10.1in)
257mm (10.1in)
332mm (13.05in)
332mm (13.05in)
Indoor unit outline
Indoor unit outline
52mm (2.05 in)
52mm (2.05in)
Right rear wall hole
Right rear wall
90mm (3.54in)
hole 90mm (3.54in)
Model E
exit the unit. Use needle nose pliers if the plastic
panel is too difficult to remove by hand.
3. Groove has been made in the knock-out panel
in order to cut it conveniently. The size of the
slot is determined by the diameter of piping.
Knock-out Panel
Knock-out Panel
4. If existing connective piping is already
embedded in the wall, proceed directly to
the Connect Drain Hose step. If there is no
embedded piping, connect the indoor unit's
refrigerant piping to the connective piping that
will join the indoor and outdoor units. Refer to
the Refrigerant Piping Connection section of
this manual for detailed instructions.
C
Refrigerant piping can exit the
indoor unit from four different
angles:Left-hand side, Right-
hand side, Left rear, Right rear.
CAUTION! Be extremely careful
A
not to dent or damage the piping
while bending them away from
the unit. Any dents in the piping
will affect the unit's performance.
Split Type Air Conditioner / User Manual