MAINTENANCE AND CLEANING

NOTICE
Prior to starting any servicing operation on
appliances that have been used, clean with Puli-Jet
plus new or Puli-Jet 2.0 a few times as explained in
the maintenance section.
Use disposable GLOVES (fig. B3), GOGGLES, MASK
and OVERALL.
MAINTENANCE AND CLEANING
• Electrical shock risk: also 230 V
• Biological danger, risk of infections from epidemic
diseases.
• High temperature.
• Compulsory direction of flow and of rotation.
Together with liquids some solid particles may be
sucked in, therefore it is necessary to have filters
in order to protect the motor and recover wanted
particles.
Aspi-Jet 6 γ is provided, like all other models, with
a debris filter 9 (Fig. C) which can be checked from
outside the cabinet; Aspi-Jet 7 γ is provided with a
filter (10) on the canister cover.
Filters must be cleaned every day. In order to remove
the filter 9, first turn the unit on and aspirate only
air for some seconds so that hoses and manifold
dry out; disconnect the power supply line, lift the
terminals from their seat and remove manifold 4
(Fig. C) pulling the filter outwards by its handle. To
check filter 10 lift bent pipe union 11 (Fig. D).
For Aspi-Jet 6 γ, every evening, once disconnected
the power supply line, loosen the two rubber bands
and remove lid: take out canister, empty and clean
(Fig. E).
can be lethal.
Fig. B3
9
4
11
3A
Fig. D
10
13
Fig. C