Operating Instructions - Metro DataVac TC90 Series Instructions For Use Manual

Insulated transport cabinet
Table of Contents

Advertisement

TC90 SERIES INSULATED TRANSPORT CABINET — INSTRUCTIONS FOR USE

OPERATING INSTRUCTIONS

A. SLIDE RACKS
The slide racks provided with your cabinet are nickel chrome-plated to insure years of corrosion-free service. The
racks are already in place when the cabinet is shipped to you. They can be removed for cleaning by first lifting up on
the rack and then swinging the bottom towards the center of the cabinet.
The slide spacing is 25/8" to accommodate lip loaded pans for TC90S; bottom loaded pans for TC90B.
The following pans may be used:
9 pans — 12" x 20" x 21/4" (TC90S)
9 pans — 12" x 20" x 25/8" (TC90S)
9 pans — 18" x 26" x 1" (TC90B)
B. CABINET START-UP
1. A nine-foot, three-wire grounded lead cord is supplied fi xed to the cabinet. The cord cannot be separated from
the cabinet.
NOTE: Before operating your cabinet be sure to unwrap the lead cord completely from bracket.
CAUTION: With the POWER switch OFF, plug the lead cord into a standard grounded 15-amp, 125-VAC receptacle.
2. Set the thermostat dial to setting 10 = HIGH.
3. Snap the POWER switch to ON. The red POWER light will now glow as will the yellow indicator light indicating that
power is on and that the heating elements are activated and heating up.
4. Allow the cabinet to PREHEAT FOR APPROXIMATELY 45 MINUTES. After that time, the thermostat can be lowered
to a setting of 6 or 7. In a room of average temperature (72°F), this should provide 150°F to 170°F. Adjustments to
the temperature may be made as necessary.
NOTE: The POWER (red) light will glow as soon as the POWER switch is switched ON and will continue to glow
until switched OFF. The yellow indicator light will go on and off as the thermostat cycles. If the yellow light is not
illuminated, this indicates that the cabinet has achieved the preset TEMPERATURE level, NOT that the unit has been
switched OFF.
It is not necessary at the end of the operating day to disrupt the temperature setting in order to turn the unit OFF. By
switching the POWER switch to OFF, the unit is no longer operating.
By switching the POWER switch to ON when resuming operations, the cabinet will attain the preset level.
4
www.metro.com
L01-144
REV K 04/22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC90 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Tc90sTc90b

Table of Contents