564 35K - Installation Overview

The CoolSmart system is designed to redirect the convective heat of the fireplaces from the front of the unit, just
above the glass, to a location higher on the wall. The use of this kit allows for reduced clearances to televisions
and a recessed cavity above the fireplace. When using this kit, disregard the standard framing dimensions and
follow the framing instructions for the CoolSmart kit.
Ceiling
Max. 120"
(3048mm)
Min. 76-7/8"
(1953mm)
Page 23 of 44
CoolSmart TV
PB24CF, PB36CF, PB36CF ST
564 25K, 564 35K, 3615HO
Min. 1-1/2" (39mm)
Min. 1-1/4" (32mm)
Television
Min. 1/4"
(7mm)
a
b
564 35K CleanFace 564 35K Standard
a
47-3/8" (1203mm)
b
33-1/8" (842mm)
17602034- 9/8/22
(sku# 98900778)
Max. 4-1/4" (108mm)
Optional Recessed Pocket
564 35k
Fireplace
(CF or Std)
47-3/8" (1203mm)
30-1/4" (769mm)
Combustible Facing
Allowed
Non-Combustible
Facing Only