Troubleshooting
Symptom
Black or white bands
on copies.
Skewed copies.
Frequent paper jams.
The Add Toner
indicator doesn't go
out after replacing
the toner container.
6-2
Check Item
Is the charger cleaner in the
CLEANER HOME POSITION?
If you are using the optional
document processor, is the slit
glass dirty?
Were the originals placed
correctly?
Is the paper loaded properly in
the cassette?
Is the paper curled, folded or
wrinkled?
Is there any jammed paper or
loose scraps of paper
remaining inside the machine?
Does the registered paper size
match the size you are actually
using?
Did you shake the new toner
container enough?
Corrective Action
Remove the process unit and
return the charger cleaner to
its home position.
Clean the slit glass.
It is also possible to use the
Scan Noise Reduction function
to make black lines on the
copies less apparent. For
details, refer to the Advanced
Operation Guide.
When placing originals on the
platen, align them against the
upper left corner.
When placing originals in the
optional document processor,
align the width guides securely
before inserting the originals.
Load the paper properly.
Replace the paper with new
paper.
Carry out the appropriate
procedure to remove the
paper.
Be sure the registered paper
size matches the size you are
actually using.
Shake the toner container
horizontally 5 or 6 times.