Operating Instruction Manual
Elektroblock EBL 263-5 Art no 911.056
5.3
12V Consumers
* 12V consumers are connected by 6,3 x 0,8 push-on plug connectors with insulated housing.
Appropriate insulated counterparts have to be used.
* The choice of cable cross-sections has to comply with EN 1648-1 or –2.
Maximum current drain must not exceed the respective fuse rating.
5.4
Water Tank Connection
* The fresh water and waste water tank are connected by 5-pole and 6-pole plug-in screw terminals.
* Tank cables are sensor leads and do not have to be protected by fuses.
6.
To Put Into Operation, Shut-Down, Maintenance
6.1
To Put Into Operation
* The Elektroblock is only fully operational when used with the filling level measurement equipment.
This equipment has to be ordered separately, see section 1.1 'Suitable Accessories'.
* Prior to power-up, special attention must be paid to:
1.
living-area battery properly connected
2.
correctly selected battery-type selector switch. See section 3.1 'Controls'.
6.2
Shut-Down
* Before and after shut-down (eg winter recess), the battery should be fully recharged.
Connect the motor home to mains supply and charge the battery for a minimum of 16 hours (80Ah
battery) or 24 hours (160Ah battery).
* Before long periods of disuse, the motor home battery should be disconnected from the 12V system.
Take off terminals at battery poles.
Caution !
To prevent battery damage the battery should be fully charged before shut-down of the
vehicle.
6.3
Maintenance
* The Elektroblock EBL 263-5 is maintenance-free.
* For cleaning use a soft moisturized cloth with a mild detergent. Do not use methylated spirit,
paint thinner, etc. Liquids must not be allowed to get into the cabinet.
7.

Malfunction

* When being on mains supply the charging module is able to charge flat batteries. For that start the
engine of the motor home for a short while until the battery voltage comes up. Please see section 3.1
'Evaluation of LED battery indicator'. All connected devices must kept switched off until the battery is
at least partly charged.
Caution !
When charging a flat battery, sensitive devices being switched on may get damaged.
* In some cases of short circuit, the main fuse of the living-area battery might blow instead of the
respective PolySwitch fuse. Please see section 3.2 '12V Fuses'.
Caution !
Danger of burning. Change defective fuses only at zero-current.
Note: this operating instruction manual is intended for the customer and has to be supplied with the device
Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, D-88677 Markdorf, Tel +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt-gmbh.de 18.05.2004
/