Download Print this page

Schaudt EBL 263-5 Operating Instructions Manual page 5

Advertisement

Operating Instruction Manual
Elektroblock EBL 263-5 Art no 911.056
To switch on and off the power supply of the waste water heater (optional)
Actuate switch with
... up
... down
Note: The waste water heater needs a considerable amount of power.
When used for long periods, the motor home should be on mains supply.
Caution !
Discharge of living-area battery with waste water heater switched on.
Inquiry of water tank filling levels
LED indication of water tank filling levels in three levels.
Actuate switch in direction of
Actuate switch in direction of
LED with symbol
LED with symbol
LED with symbol
No LED indication
Note: Inquiry of water tank filling levels is for temporary use only. The used method of measurement is
not suitable for continuous operation or long inquiries.
Caution !
Continuous operation or long inquiries will damage rod sensors or tank sensors.
Mains supply indicator
230V
3.2
Additional Features
Battery-type selector switch The mains supply of the EBL has to be disconnected prior to actuating
Caution !
An incorrectly set battery-type switch may damage the batteries and there may be an
explosion-hazard caused by detonating gas.
Note: this operating instruction manual is intended for the customer and has to be supplied with the device
Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, D-88677 Markdorf, Tel +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt-gmbh.de 18.05.2004
symbol ...
→ The waste water heater may be switched on. Yellow indicator lamp is on.
→ The waste water heater cannot be switched on. Yellow indicator lamp is off.
→ Filling level of fresh water tank is shown
→ Filling level of waste water tank is shown
is on → water tank full
is on → water tank approx half full
is on → water tank approx a quarter full
→ water tank empty
The yellow LED indicates that the EBL is connected to 230V
the battery-type selector switch which is situated on the back of the EBL.
This switch has to be set according to the types of batteries used (lead-
acid or lead-gel) before the EBL is put into operation.
The switch ensures an optimum charge of the connected battery type.