Paviro call station emergency button

Advertisement

Communications Systems - PVA-1EB Call station emergency button
Assembly in call station
1. Disconnect the call station from all connectors.
2. Unscrew the call station baseplate (4 screws ➊).
3. Carefully remove the baseplate from the upper
part, start on the top left corner of the call sta-
tion.
4. Unplug the connecting cable from the CN1 plug
connector ➋.
5. Prepare installation location ➌: Use a sharp object
(scriber or similar) to carefully punch through and
cut out the pre-cut rectangle on the inside of the
housing. Perform any follow-up work that may be
required to the installation location (e.g. filing,
trimming).
6. Mount the button into the installation location,
and press in evenly (it must be possible for the
cover cap to open upward).
7. Depending on whether the right/middle/left in-
stallation location is used, plug the ribbon cable ➍
into plug connector CN201/CN202/CN203 on the
circuit board.
8. Plug the connecting cable into CN1 again.
9. Carefully re-attach the call station baseplate.
10. Re-connect the connections.
11. Configure the button using the software.
3
2
Parts included
Quantit
Component
y
1
Button element with cover
1
Preconfigured 4-pin connecting cable
1
Installation note
Technical specifications
Mechanical
Product dimensions (Height x Width
x Depth)
Net weight
Shipping weight
2 | 3
1
30 mm x 21 mm x 21 mm
0.01 kg
0.02 kg