Chapter 2. Description
The power and RS-485/RS-422 terminals are placed on the top side of the unit. The
RS-232 and Ethernet connectors are placed on the bottom side of the unit as shown in
the following illustration:
TOP VIEW
BOTTOM VIEW
Figure 2.1: Location of connectors
  Clear front cover
  Serial port 1 RS-232 connector
  Serial port 2 RS-232 connector
  Ethernet connector
  DIN rail clip
  Power LED
  Ethernet link LED
  Device status LED
  Communication status LED
  Power terminals
  Serial port 1 and 2 RS-485 or serial port 1 RS-422 terminals

LED indicators

Four LEDs located at the front panel indicate the status of the device. The LEDs assist
maintenance personnel in quickly identifying wiring or communication errors.
A LED test is exercised at power-up, cycling each LED off, green and then red for
approximately 0.25 seconds. At the same time the power-on self test of the device is
performed.
UMMBDC200-2201