NOTE: Fluid Control Module (FCM) connection to the
NOTE:
NOTE:
system is temporarily disabled during the installation
of upgrade or key tokens.
1. Ensure the system is inactive.
2. Remove access cover (AJ).
3A3465A
Key Tokens
Tokens
Key
Tokens
3. Insert and press token (T) firmly into slot.
NOTE:
NOTE: There is no preferred orientation of token.
NOTE:
4. Press and hold button the push button (AK) for
three seconds and then release. The red LED
(AL) will flash until the software is uploaded.
5. Remove token (T) when software has
successfully uploaded or key token is no longer
required.
NOTE:
NOTE: Upgrade tokens can be removed once
NOTE:
the software has been successfully uploaded.
If key tokens are used by your Graco Control
Architecture based system, they must remain in
the FCM for features or settings to be enabled.
Key tokens are not present on all Graco Control
Architecture based settings.
6. Replace the access cover (AJ).