Chamberlain ELITE SL585UL Installation Manual page 12

Ac slide gate operator
Hide thumbs Also See for ELITE SL585UL:
Table of Contents

Advertisement

Post mount installation
Retro-fit installation
The operators come from the factory configured to mount to an inside the
frame post mount dimension of 26" (66 cm) (outside to outside of
posts). The frame comes slotted to accommodate posts 24-1/8" (61 cm)
to 26" (66 cm), outside to outside. NOTE: If you are replacing a SL580,
the frame will require adjustment to 24-1/8".
New installation
1. Locate and anchor two posts made of 3" (7.6 cm) outer diameter
heavy walled pipe. Posts should be parallel and square to the gate.
2. Locate electrical conduit, as required, prior to pouring concrete.
3. Secure operator to posts using four 3" (7.6 cm) U-bolts and
hardware provided.