AXIS C12 Series
Specifications
Balanced microphone (with or without phantom power)
or line, "hot" signal
Digital signal
Stereo unbalanced microphone (with or without electret
power) or line, "left"
Audio output
1 Tip
Channel 1, unbalanced line, mono
Balanced line, "hot" signal
Stereo unbalanced line, "left"
Channel 1, unbalanced line
The internal microphone is used by default; the external microphone is used when connected.
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Supervised input - Enables possibility to detect tampering on a digital input.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, through an event or from the product's webpage.
4-pin terminal block
Function
DC ground
DC output
Configurable
(Input or Output)
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–4
Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
Balanced microphone (with or without phantom
power) or line, "cold" signal
Ring power if selected
Stereo unbalanced microphone (with or without
electret power) or line, "right"
2 Ring
Channel 1, unbalanced line, mono
Balanced line, "cold" signal
Stereo unbalanced line, "right"
Channel 2, unbalanced line
41
Ground
Ground
Ground
3 Sleeve
Ground
Ground
Ground
Ground
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA