INTRODUCTION

1.1 | Functional Description

The PF3100 Ion Pilot card is used to generate a spark to ignite a pilot burner and to detect the flame of
both a pilot and main burner. This card is powered through the PFRN network via a Controller class or
Network class card (typically a BMS Controller card or a Network Switch Card).

1.2 | System Requirements

Specific system requirements will vary according to which Controller class card is connected to the Ion
Pilot card. For additional information, refer to the Hardware Guide corresponding to the Controller type
card (e.g., BMS Controller card) specific to your application.
IGNITION COIL WIRING
The Ion Pilot card is usually sold in a Class I, Div 1 / Zone 1 explosion proof enclosure (EPX) which also
includes an ignition coil. This allows the ignition and flame monitoring to be located close to the associat-
ed burner which reduces the need for long ignition wires.
Internal Ignition Coil
Red
Ion +
6
White
Coil +
9
Black
Coil -
8
WIRE REQUIREMENTS
Single Rod Pilot
WIRE LOCATION
5
{
+
9
10
Coil
7
8
6
EGND
7
Ion
+
6
5
Main Ion
+
Ignition Wire
CONNECTION DESCRIPTION
Board to Main Flame Detect
Rod
Coil to Pilot Ignition Rod
Ignition
Board to Burner
Coil
Board to Pilot Flame Detect
10
(Dual Rod Pilot only)
4
Ignition
10
Rod
WIRE TYPE AND MIN GAUGE
7 mm ignition wire
7 mm ignition wire
14 AWG
Straight
7 mm ignition wire
Silicone
Boot
Ferrule
Straight
Ferrule
Silicone
MAX LENGTH
Each wire should be limited to
25 ft maximum
Pilot Ignition and
Flame Detect Rod
Main Flame
Detect Rod

Advertisement

Table of Contents