General Technical Data

9.3.4 Conductor Cross-sections

Type
Conductor cross-sections
Screw-type terminals Main conductor:
With box terminal
Front clamping point
• Finely stranded with end sleeve
connected
• Finely stranded without end sleeve
• Stranded
• Ribbon cable conductors
(number x width x thickness)
• AWG conductors, solid or stranded
Rear clamping point
• Finely stranded with end sleeve
connected
• Finely stranded without end sleeve
• Stranded
• Ribbon cable conductors
(number x width x thickness)
• AWG conductors, solid or stranded
Both clamping points
• Finely stranded with end sleeve
connected
• Finely stranded without end sleeve
• Stranded
• Ribbon cable conductors
(number x width x thickness)
• AWG conductors, solid or stranded
• Terminal screws
- Pickup torque
Screw-type terminals Main conductor:
With box terminal
Front or rear
• Finely stranded with end sleeve
clamping point
• Finely stranded without end sleeve
connected
• Stranded
• Ribbon cable conductors
(number x width x thickness)
• AWG conductors, solid or stranded
Both clamping points
• Finely stranded with end sleeve
connected
• Finely stranded without end sleeve
• Stranded
• Ribbon cable conductors
(number x width x thickness)
• AWG conductors, solid or stranded
Screw-type terminals Main conductor:
Without box terminal/rail connection
• Finely stranded with cable lug
• Stranded with cable lug
• AWG conductors, solid or stranded
• Connecting bar (max. width)
• Terminal screws
- Pickup torque
9-14
mm
mm
mm
mm
AWG
mm
mm
mm
mm
AWG
mm
mm
mm
mm
AWG
mm
mm
mm
mm
AWG
mm
mm
mm
mm
AWG
mm
mm
AWG
mm
NM
lb. in
1)
When connecting cable lugs to DIN 46235 use 3RT19 56-4EA1 terminal cover for conductor cross-sections from
95 mm² to ensure phase spacing.
2)
When connecting cable lugs to DIN 46234, the 3RT19 66-4EA1 terminal cover must be used for conductor cross-
sections of 240 mm² and more as well as DIN 46235 for conductor cross-sections of 185 mm² and more to keep
the phase clearance.
3RW44 2.
3RT19 55-4G (55 kW)
2
16 ... 70
2
16 ... 70
2
16 ... 70
min. 3 x 9 x 0.8,
max. 6 x 15.5 x 0.8
6 ... 2/0
2
16 ... 70
2
16 ... 70
2
16 ... 70
min. 3 x 9 x 0.8,
max. 6 x 15.5 x 0.8
6 ... 2/0
2
max. 1 x 50, 1 x 70
2
max. 1 x 50, 1 x 70
2
max. 2 x 70
max. 2 x (6 x 15.5 x 0.8)
max. 2 x 1/0
M10 (hexagon socket, A/F4) M12 (hexagon socket, A/F5)
10 ... 12
90 ... 110
3RT19 56-4G
2
16 ... 120
2
16 ... 120
2
16 ... 120
min. 3 x 9 x 0.8
max. 6 x 15.5 x 0.8
6 ... 250 kcmil
2
max. 1 x 95, 1 x 120
2
max. 1 x 95, 1 x 120
2
max. 2 x 120
max. 2 x (10 x 15.5 x 0.8)
max. 2 x 3/0
2
1)
16 ... 95
2
1)
25 ... 120
4 ... 250 kcmil
17
M8 x 25 (A/F13)
10 ... 14
89 ... 124
3RW44 3., 3RW44 4.
3RW44 5.
3RT19 66-4G
70 ... 240
70 ... 240
95 ... 300
min. 6 x 9 x 0.8
max. 20 x 24 x 0.5
3/0 ... 600 kcmil
120 ... 185
120 ... 185
120 ... 240
min. 6 x 9 x 0.8
max. 20 x 24 x 0.5
250 ... 500 kcmil
min. 2 x 50; max. 2 x 185
min. 2 x 50; max. 2 x 185
max. 2 x 70; max. 2 x 240
max. 2 x (20 x 24 x 0.5)
min. 2 x 2/0;
max. 2 x 500 kcmil
20 ... 22
180 ... 195
2)
50 ... 240
50 ... 240
2)
70 ... 240
70 ... 240
2/0 ... 500 kcmil
1/0 ... 500 kcmil
25
60
M10 x 30 (A/F17)
M12 x 40
14 ... 24
20 ... 35
124 ... 210
177 ... 310
SIRIUS 3RW44 manual
GWA 4NEB 535 2195-02 DS 02