Texas Instruments ADS1298RECG-FE User Manual
Texas Instruments ADS1298RECG-FE User Manual

Texas Instruments ADS1298RECG-FE User Manual

Ecg front-end performance demonstration kit
Table of Contents

Advertisement

Quick Links

ADS1298RECG-FE
ECG Front-End Performance Demonstration Kit
User's Guide
Literature Number: SBAU181B
March 2011 – Revised Janurary 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADS1298RECG-FE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Texas Instruments ADS1298RECG-FE

  • Page 1 ADS1298RECG-FE ECG Front-End Performance Demonstration Kit User's Guide Literature Number: SBAU181B March 2011 – Revised Janurary 2016...
  • Page 2: Table Of Contents

    Analog Input Signals ..................Appendix A BOM, Layout, and Schematics ................ADS1298R Front-End Board Schematics ..................Printed Circuit Board Layout Table of Contents SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 3 Optional External Hardware (Not Included) ..............ADS1298R Power-Supply Recommendations ....................Appendix C Software Installation ....................Minimum Requirements ....................Installing the Software .......................... Revision History SBAU181B – March 2011 – Revised Janurary 2016 Contents Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 4 Bottom Component Placement and Routing ..................Internal Ground Plane (Layer 2) ................... Internal Power Plane (Layer 3) ..................... ECG Cable Schematic List of Figures SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 5 Recommended Power Supply for ADS1298R ....................Initialization of ADS1298R ......................License Agreement ......................Installation Process ................ Completion of ADS1298R Software Installation SBAU181B – March 2011 – Revised Janurary 2016 List of Figures Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 6 CLK Jumper Options ..................External Reference Jumper Options ......................... Test Signals ..................... Serial Interface Pinout ..................... Bill of Materials: ADS1298R List of Tables SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 7: Ads1298R Overview

    (EEG) applications. The ADS1298R is intended for prototyping and evaluation. This user's guide includes a complete circuit description, schematic diagram, and bill of materials. The following related documents are available through the Texas Instruments web site at www.ti.com. Device...
  • Page 8: Introduction

    • File printing for post-processing of raw ECG data • Sets the ADS1298R register settings via easy-to-use graphic user interface (GUI) software ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 9: Features Not Supported In Current Version

    The complete kit includes the following items: • ADS1298R ECG FE printed circuit board (PCB), Rev A • MMB0 (Modular EVM motherboard, Rev C or higher) SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 10: Quick Start

    This section provides a QuickStart guide to quickly begin evaluating the EVM using the ADS1298RECG- FE software. Default Jumper/Switch Configuration Figure 2 shows the jumpers found on the ADS1298RECG-FE EVM and the respective factory default conditions for each. Figure 2. ADS1298RECG-FE Default Jumper Locations Table 1 lists the jumpers and switches and the factory default conditions.
  • Page 11: Ads1298Recg-Fe Default Jumper/Switch Configuration

    Quick Start www.ti.com Table 1. ADS1298RECG-FE Default Jumper/Switch Configuration Jumper Default Position Description Installed RLD feedback Installed 1-2 AVDD selected for bipolar supply operation selected (AVDD = +2.5V) Header Not Installed External Vref buffer not connected Installed EVM +5V provided from J4 (power header)
  • Page 12: Ads1298Recg-Fe Operation

    MMB0 J13B → Open • Refer to Appendix B2 for details about the MMB0 power supply 3. Install the ADS1298RECG-FE software using the latest software version. The latest software can be downloaded from the ADS1298RECG-FE product page. Double click the installer and follow the instruction to complete the software installation.
  • Page 13: Using The Ads1298Recg-Fe Software

    Using the ADS1298RECG-FE Software The ADS1298RECG-FE software provides complete control over all the settings of the ADS1298R. By using the user interface (UI), the ADS1298R control registers can be manipulated to evaluate the various options available on the device.
  • Page 14: Application User Menu

    The ACQUIRE control starts the acquisition process. When pressed, the software will collect the requested number of samples from the ADS1298R. All points collected during an acquisition process will be contiguous points. ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 15: About Tab

    Additional indicators are present to provide device information (Device ID and Rev) and software information (Firmware Version). The About tab should be the first screen displayed at startup (see Figure SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 16: Adc Register Tab

    Reset control is pressed. Device Defaults resets the device to the device defaults; Programmed Defaults resets the device, then writes the default values for using this software application. ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 17: Internal Reference And Buffer Connections

    AVDD AVDD ADS129x ADS129x 10MW 10MW a) Pull-Up/Pull-Down Resistors b) Current Source Figure 10. Lead-Off Excitation Options SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 18: Input Multiplexer For A Single Channel

    MUX[2:0] = 011 MvddN MUX[2:0] = 100 TempN MUX[2:0] = 101 TestN INT_TEST TESTN_PACE_OUT2 INT_TEST Figure 11. Input Multiplexer for a Single Channel ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 19: Loff And Rld Tab

    AVDD). Further details of these registers and lead-off function are located in the Applications Section of the device data sheet. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 20: Loff_Statp And Loff_Statn Comparators

    The Right Leg Drive Derivation Control Registers enable the user to set any combination of positive and/or negative electrodes to derive the RLD voltage that is fed to the internal right leg drive amplifier. ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 21: Gpio And Other Register Tab

    The Respiration Control Register allows the user to configure the respiration modulation and demodulation on Channel 1, Respiration Phase, and set the Respiration Control Signal. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 22: Wilson Central And Augmented Lead Routing Diagrams

    ADS1294/6/8 avF_ch6 avF_ch5 avF_ch7 IN5P IN5N IN6P To Channel IN6N PGAs IN7P IN7N Figure 15. Wilson Central and Augmented Lead Routing Diagrams ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 23: Device Registers Settings

    16. Refresh Registers control updates the register map values with the current register settings of the ADS1298R. Figure 16. Device Registers Settings SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 24: Analysis Tab

    MUX is selected as Input Short, PGA gain is set to 6 (default), and the sample rate is set to 500 samples per second (SPS). Figure 18. Scope Analysis Tab (Noise Levels for Each Channel Shown) ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 25: Zoom Tool Options

    Channel 2. In this case, the tool makes it much easier to determine that the noise seen on the ECG waveform is a result of 50Hz/60Hz line cycle noise. Figure 19. Zoom Tool Options SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 26: Histogram Bins For 12-Lead Ecg Signal

    20) is clicked. The analysis window shows the mean, V , and V channel amplitude bins. Figure 21. Statistics for the Signal Amplitude of Eight ECG Channels ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 27: Fft Graph Of Normal Electrode Configuration

    Note that pressing the Reference button toggles between dBFS (decibels, full-scale) and dBc (decibels to carrier). Figure 23. AC Analysis Parameters: Windowing Options SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 28: Fft Analysis: Input Short Condition

    As with the Analysis, Histogram, and Scope tool, this zoom function allows a closer examination of the FFT at frequencies of interest, as shown in Figure ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 29: Fft Plot Using Zoom Tool

    Using the ADS1298RECG-FE Software www.ti.com Figure 26. FFT Plot Using Zoom Tool SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 30 The Simulated Respiration Frequency set the respiration frequency that the on-board respiration circuitry will simulate when collecting data. The Statistical Data group provides two calculated parameters from the displayed data, Mean and Noise. ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 31: Ecg Display Tab Showing Lead I-Iii And Augmented Leads

    To disable the filter, the Enable checkbox should be unchecked. Any combination of the three digital filters can be used by enabling the respective filter. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 32: Ecg Signal Zoom Feature For Six Leads

    Processing Filters group (right side of the box). NOTE: The digital filters are not part of the ADS1298R. These are digital filters implemented in the UI to aid in the evaluation of the ADS1298RECG-FE. 4 - Zoom Feature The zoom feature is available to allow the user to navigate and view all signals at the same time, as...
  • Page 33: Save Tab

    The Save To File button saves all the data files that were selected using the check boxes to the selected directory. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 34: Save Tab

    Using the ADS1298RECG-FE Software www.ti.com Figure 30. Save Tab ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 35: Ads1298Recg-Fe Input Signals

    Detailed instructions for using the ECG Display tab are provided in Section 3.5.5. Figure 31. Example of Internal Test Signals Viewed on the ECG Display Tab SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 36: Temperature Sensor

    Temperature = (0.1447 – 0.145300) / 0.00049 + 25 = 23.78°C A more detailed description of the Scope tab is provided in Section 3.5.1. Figure 33. Eight-Channel Read of Internal Temperature ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 37: Normal Electrode Input

    The RLD measurement takes the voltage at the RLDIN pin and measures it on the PGA with respect to + AV )/2. This feature is beneficial if the user would like to optimize the gain of the RLD loop. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 38: Lead Derivation

    WCT2 registers provide controls to select any of the eight inputs (CH1P to CH4P, CH1M to CH4M) for routing to the three integrated WCT amplifiers. The ADS1298RECG-FE is configured for 12-lead ECG inputs, with the limb electrodes connected as shown in Table 2.
  • Page 39: Pace Detection

    RL electrode falls off). Refer to the ADS1298R product data sheet additional details. 4.8.2 Driving the RLD Cable Shield Apart from the RLD signal, the ADS1298RECG-FE also offers three options to drive the cable shield: • In-phase RLD signal • Out-of-phase RLD signal •...
  • Page 40: Digitization Of Pace Signal Using Ads1298R

    ADS1298R. The signal must be AC coupled to obtain the waveform\ shown below. Figure 35. Digitization of PACE Signal Using ADS1298R ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 41: Evaluation Of The Ads1298R Respiration Function

    JP36. Figure 36. Respiration Evaluation with Onboard Circuitry SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 42 500SPS. To obtain better resolution, these results must be low-pass filtered. Figure 38 shows the result after the signal has been processed through a 2Hz low-pass filter. ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 43: Channel 1 Δ Impedance Measurement

    Evaluation of the ADS1298R Respiration Function www.ti.com Figure 38. Results After Low-Pass Filtering Figure 37. Channel 1 Δ Impedance Measurement SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 44: Testing With Patient Simulator

    The peak-to-peak output can then be calculated as shown in Equation V = R I = 1 29.15 = 29.1 V · · ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 45: Channel 1 Result For R

    Figure 39. Channel 1 Result for R These two approaches to performing respiration measurements show that the internal respiration circuitry of the ADS1298R can resolve down to 100mΩ. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 46: Ads1298R Daughter Card Hardware Details

    ADS1298R Daughter Card Hardware Details The ADS1298RECG front-end evaluation board is configured to be used with the TI MMB0 data converter evaluation platform. The ADS1298RECG-FE board is a four-layer circuit board. The board schematic and layout are provided in Appendix The ADS1298R can be used as a demonstration board for standard, 12-lead ECG applications with an input configuration of 10 electrodes.
  • Page 47: Ads1298Recg-Fe Default Jumper/Switch Configuration

    ADS1298R Daughter Card Hardware Details www.ti.com Table 5. ADS1298RECG-FE Default Jumper/Switch Configuration (continued) Jumper Function Settings ECG shield drive buffer 1-2: ECG shield drive connected to RLDOUT JP17 input(Header Not Installed) 2-3: ECG shield drive connected to RLDINV 1-2: CLK connected to DSP (J3.17)
  • Page 48: Power Supply

    ADS1298R Daughter Card Hardware Details www.ti.com Table 5. ADS1298RECG-FE Default Jumper/Switch Configuration (continued) Jumper Function Settings 1-2: Connect RESP MOD- to JP33 JP34 CH1- Input Signal Mux 2-3: Connect ECG_LA to JP33 1-2: Connect RESP MOD+ to JP33 JP35 CH1+ Input Signal Mux...
  • Page 49: Clock

    Alternatively with appropriate user configuration, these pins may provide PACE detection for use with external PACE detection circuitry (see PACE Detect Register in Section 3.4.4). SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 50: Digital Signals

    The ADS1298R provides users the option to feed in standard ECG signals from a patient simulator to the DB15 connector, or to feed inputs from any arbitrary signal source directly to the ADS1298R. ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 51: Fluke Simulator Configuration

    NOTE: Ensure that the single-ended signal has an offset equal to the voltage supplied at the negative input of the channel. SBAU181B – March 2011 – Revised Janurary 2016 ADS1298R Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 52: Appendix A Bom, Layout, And Schematics

    ADS1298R PCBs. ADS1298R Front-End Board Schematics The ADS1298R schematic is appended to this document. BOM, Layout, and Schematics SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 53: Printed Circuit Board Layout

    10-lead ECG cable for Philips/HP-snap, button (Part No: 010302013); http://www.biometriccables.com/index.php?productID=692 • 10-lead ECG cable for Philips/HP-Clip-on type (Part No: 010303013A); http://www.biometriccables.com/index.php?productID=693 SBAU181B – March 2011 – Revised Janurary 2016 BOM, Layout, and Schematics Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 54: Ecg Cable Schematic

    ECG Cable Details www.ti.com Another compatible cable for the ADS1298R: HP/Philips/Agilent-compatible 10-lead ECG cable. Figure 47. ECG Cable Schematic BOM, Layout, and Schematics SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 55: Bill Of Materials: Ads1298R

    3-Position Jumper _ 0.1" spacing Samtec TSW-103-07-T-S JP22, JP23, JP24, JP34, JP35, JP36 JP26 - JP32 2x2x.1, 2-Pin Dual Row Header Samtec TSW-102-07-T-D SBAU181B – March 2011 – Revised Janurary 2016 BOM, Layout, and Schematics Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 56 IC Comparator P-P Nanopwr 8-SOIC TLV3491AID IC MCU 16-Bit 14TSSOP MSP430G2121IPW14R OSC1 OSC 2.0480 MHz 3.3V HCMOS SMT FXO-HC735-2.048MHz BOM, Layout, and Schematics SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 57 (refer to Section 6.7.1). Figure 48. 15-Pin, Shielded Connector from Biometric Cables SBAU181B – March 2011 – Revised Janurary 2016 External Optional Hardware Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 58: Cardiosim Ecg Simulator Tool

    Figure 49. 15-Pin, Twisted Wire Cable to Banana Jacks Figure 50. 15-Pin, Twisted Wire Cable Figure 51. Cardiosim ECG Simulator Tool External Optional Hardware SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 59: Recommended Power Supply For Ads1298R

    ADS1298R with a battery source. This configuration minimizes the amount of noise pickup seen at the digitized output of the ADS1298R. Figure 52. Recommended Power Supply for ADS1298R SBAU181B – March 2011 – Revised Janurary 2016 External Optional Hardware Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 60 Figure 53 through Figure You must accept the license agreement (shown in Figure 54) before you can proceed with the installation. Software Installation SBAU181B – March 2011 – Revised Janurary 2016 Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 61: Initialization Of Ads1298R

    Deleted "provided in the EVM kit" from Section B.2. NOTE: Page numbers for previous revisions may differ from page numbers in the current version. SBAU181B – March 2011 – Revised Janurary 2016 Revision History Submit Documentation Feedback Copyright © 2011–2016, Texas Instruments Incorporated...
  • Page 62 AVDD AVDD AVDD AVDD AVSS AVDD AVSS AVDD AVSS C78 NI C27 NI 22.1k 22.1k 22.1k JP11 ECG_V2 ECG_V4 ECG_V6 ECG_V2 ECG_V4 ECG_V6 47pF 47pF 47pF 47pF 47pF 47pF AGND AGND AGND AGND AGND AGND AVSS AVSS AVSS AVDD AVDD AVSS AVDD AVDD...
  • Page 63 AVDD AVDD AVDD AVDD AVDD 0.1uF AGND AVSS AVSS AGND ECG_SHD_DRV ECG_SHD_DRV JP17 AVDD AVDD DVDD R5 NI 0.1uF 0.1uF 0.1uF AGND AVSS ECG_RL ECG_RL AVSS AGND AGND AVDD 1.5nF AVSS AVSS JP16 AVSS VCAP3 AVDD JP26 0.1uF IN8N IN8P 1000pF AVSS TP11...
  • Page 64 External Reference Optional External Reference AVDD TEMP AVDD TRIM AVSS C41 NI AGND AVSS JP3 NI VREFP JP25 AVDD C42 NI TEMP AGND TRIM AVSS AVSS AVSS NOT INSTALLED 12500 TI Boulevard. Dallas, Texas 75243 Title: ADS1298R ECG FE Engineer: Tom Hendrick DOCUMENTCONTROL # REV:...
  • Page 65 VCC_5v VCC_-5v 3.3uH 3.3uH 10uF 10uF 10uF 10uF AGND AGND TPS60403 AGND AGND AGND +3.0V 3.3uH AVDD 2.2uF 10uF 10uF AGND AGND AGND NR/FB TPS73230 0.1uF AGND AGND AGND TP13 +2.5V 3.3uH 2.2uF 10uF 10uF AGND 49.9K AGND AGND NR/FB TPS73201 AGND 46.4K...
  • Page 66 DVDD DVDD For MMB0 - JP21 and 23 short 1-2, JP22 short 2-3 C71 100uF DVDD AGND 0.1uF JP23 CLKSEL JP24 VCC_5v VCC_1.8V SPI_CLK TP10 SPI_CS VCC_3.3V GPIO1 JP21 RESETB SPI_IN 11 12 GPIO2 11 12 SPI_OUT 13 14 VCC_3.3V 100uF 0.1uF 13 14...
  • Page 67 STANDARD TERMS AND CONDITIONS FOR EVALUATION MODULES Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, or documentation (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance with the terms and conditions set forth herein. Acceptance of the EVM is expressly subject to the following terms and conditions.
  • Page 68 FCC Interference Statement for Class B EVM devices NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 69 【無線電波を送信する製品の開発キットをお使いになる際の注意事項】 開発キットの中には技術基準適合証明を受けて いないものがあります。 技術適合証明を受けていないもののご使用に際しては、電波法遵守のため、以下のいずれかの 措置を取っていただく必要がありますのでご注意ください。 1. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用 いただく。 2. 実験局の免許を取得後ご使用いただく。 3. 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。 上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・イ ンスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル 3.3.3 Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page 電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧くださ い。http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page SPACER EVM Use Restrictions and Warnings: 4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.
  • Page 70 Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief in any United States or foreign court. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2015, Texas Instruments Incorporated...
  • Page 71 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue.

Table of Contents