OPERATING INSTRUCTIONS / MAIN SEAL REPLACEMENT
Page 1 of 3
60V & 70V Series Valve Connectors
DESCRIPTION: Sleeve Activated Connectors for Sealing Male
Threads and Formed Tube Ends.
60 Series for
Male Threads
CAUTION: 60V & 70V Connectors are internally valved. Disconnecting
while pressurized can cause rapid separation. Termination pressure
should be relieved prior to disconnecting connector.
Connecting while pressurized is doable but not recommended.
Example of connection forces; At 80psi with a Body Size 3 connector
the force to connect is approximately 44 lbs.
Body Size 4 connector is approximately 56 lbs. at 80psi.
Please thoroughly read the instructions prior to operating the connector. This
connector is designed to provide a safe, reliable leak-tight seal and
connection when properly maintained and operated.
• The connector is designed to mate with a specific application. Verify the
application prior to the introduction of pressure or processing. Use only in
a safe environment. Safety chains and guards are recommended for all
applications.
• Connectors are NOT designed for permanent connections and are for
temporary connections only.
DO NOT EXCEED pressure rating as marked on connector or
corresponding literature. Before using, verify that this pressure rating is
within your working pressures.
70 Series for Tube
Configurations

Installation

Operation

Connector Maintenance
Safety Warnings - Guidelines
INSTALLATION:
1. Connect media hose/fitting to the termination port on connector.
a. Pipe tape and or thread sealant is recommended.
OPERATION:
1. Slide sleeve back and collets will open.
COLLETS
SLEEVE BACK
COLLETS OPEN
2. Insert male end of the component to be tested into collets and press
against connector. Spring action forces knurled sleeve forward, collaps-
ing collets to the gripping and sealing position.
Note to Operator; The Type 60/70 Connector will
3.
connect better when you do the following. Hold exposed
area of Body at termination end of connector. Try to
keep hands free from the sleeve as you connect to your
test piece.
TERMINATION
PORT
BODY
www.fastestinc.com
Roseville, MN
Toll Free at 1-800-444-2373
Fax 651-645-7390
WP144 Rev B
6/25/2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 60V Series and is the answer not in the manual?

Questions and answers

Summary of Contents for FasTest 60V Series

  • Page 1 OPERATING INSTRUCTIONS / MAIN SEAL REPLACEMENT Page 1 of 3 Installation 60V & 70V Series Valve Connectors • Operation • DESCRIPTION: Sleeve Activated Connectors for Sealing Male Main Seal Replacement • Threads and Formed Tube Ends. Connector Maintenance • Safety Warnings - Guidelines •...
  • Page 2 OPERATING INSTRUCTIONS / MAIN SEAL REPLACEMENT Page 2 of 3 4. Attempting to connect while connector is still pressurized is doable but MAIN SEAL REPLACEMENT: not recommended. NOTE: IN MOST CASES THE MAIN SEAL CAN BE EXTRACTED AND REPLACED IN THE STEPS THAT FOLLOW. IF CONNECTOR MUST BE NOTE: DO NOT FORCE CONNECTOR ONTO TEST PART WHEN DIS-ASSEMBLED TO REPLACE MAIN SEAL, SEE INSTRUCTION WP143.
  • Page 3 FasTest, Inc. warrants its products against defects of workmanship and/or material for 12 months from the date of the sale by FasTest, Inc. This warranty is void if the product is misused, tampered with, or used in a manner that is not in accordance with FasTest, Inc.

This manual is also suitable for:

70v series

Table of Contents