TECHNICAL DATA OF MOTOR CONTROL:
Voltage
230VAC
Transformer
230/24VAC minimum60VA
Output motor
24VDC max.
Supply accessories
24VDC - 100mA
Operating temperature
-20°C - +55°C
Degree of protection
IP54
PE
TRANSFORMER
230VAC
250V/2A
L
N
230VAC
PE
INPUT
24VAC
250V/2A
-
+
MOTOR
MOTOR
24V/150mA
BRN GRN WHT YEL
30VDC
MASTER
SECOND
/ LAMP
+ -
WIRING OF CONTROL / SUMMARY
a) start with still dead 230Volts supply cable on the left side of the box.
b) Attach cable eye to ground wire. Then connect ground wire to base
plate with washer and nut (exactly as shown in picture detail).
Connect all other cables to control.
Attention:Check repeatedly that cable colours are connected correctly
to motor. Otherwise motor might be damaged or will not operate
properly. Pay special attention when using distribution boxes.
We recommend the following accessories: LA400-JB40E Kit for
cable extension of one installation unit. Consists of 12m of
cable 6-pole with identical colours, distribution box IP65,cable screw
joints and fastening material
COM PHOTO
BRN GRN WHT YEL
MASTER
SECOND
P1
P2
P3
1/2 MOTOR
STOP/8.2K
Ω
RADIO
OPEN / PED
801719
JP1
JP2
STOP/8.2K
PHO2
PHO1
LEARN
DIAGNOSTIC
COM STOP/*
8.2 Ω
1
2
8.2
Ω
+
+
+
+
+