Download Print this page

493K K-Paq Junior Owner's Manual page 32

Advertisement

Assembly of Get You Started (GYS)
7. When first applied the high temperature silicone leave for 45minutes to
allow for a "skin" to form as this helps reduce the amount of oozing
caused when replacing the cover on the connector plug
8. With the connector plug fitted the other end of the cable needs to be prepared.
Strip back the sheathing by 10mm and twisted the two wires together. Snip the
twisted wire to leave a thermocouple junction of 3-5mm. The point is where the
temperature will be measured.
Thermocouple Leads
32

Advertisement

loading

Related Products for 493K K-Paq Junior