Download Print this page

493K K-Paq Junior Owner's Manual page 16

Advertisement

Initial set-up
1.
Using the mechanical interface fixtures and the instructions provided with the 493K slip rings, the slave TXR1A
units are affixed adjacent to the slip rings on each rotating arm.
2.
Insert the K type thermocouple plugs issuing from the slip rings into the appropriate sockets on each slave
TXR1A unit.
3.
Place the K-Kord disc into the CD-ROM of the PC and install the K-Kord software.
4.
Run up the K-Kord software, click the Preferences tab and select the PC serial comport to be used for
connection to the master TXR1A unit, e.g., COM1, COM2, COM3 or COM4.
5.
Any problems allocating the correct comport, once K-Kord is installed, click the Tools drop down menu on the
toolbar and select "Automatic COM port Detection Wizard" and follow the step by step instructions.
6.
Site the master TXR1A unit adjacent to the PC and connect the RS232 serial cable between the master and the
selected comport of the PC.
MCM03022016