Displaying Devices Within The Fabric; Checking The Firmware Version; Setting The Switch Date And Time - Compaq StorageWorks Fibre Channel SAN Switch 2 Installation Manual

Table of Contents

Advertisement

Displaying Devices within the Fabric

To verify that you have fabric wide connectivity when you install a new switch, display the
fabric wide device count from the newly installed switch. Use these steps to display the fabric.
1. Login to the switch as the admin user.
2. At the command line enter the following command:
nsAllShow
This command displays all the connected devices in the fabric.

Checking the Firmware Version

Use these steps to display the SAN Switch 2/16 firmware version.
1. Login to the switch as the admin user.
2. At the command line enter the following command:
version
This command displays the Kernel version, and Fabric OS release number.

Setting the Switch Date and Time

All switches maintain current date and time in non-volatile memory. Date and time are
used for logging events. Switch operation does not depend on the date and time; a
switch with an incorrect date and time value still functions properly.
Uses these steps to set the date and time of a switch.
1. Login to the switch as the admin user.
2. At the command line enter the following command:
date "MMDDhhmmYY"
where:
— MM is the month, valid values are 01-12.
— DD is the date, valid values are 01-31.
— hh is the hour, valid values are 00-23.
— mm is minutes, valid values are 00-59.
— YY is the year, valid values are 00-99.
Fibre Channel SAN Switch 2/16 Installation Guide
Managing the Fibre Channel SAN Switch 2/16