2. Now power on your computer and connect the ACU19V to the Mains supply (J12).
3. Insert the CD-ROM into the computer's drive and inspect it's contents through the 'My
Computer' icon on your desktop. Double-click to the 'ChipTool.exe' program in the 'ChipTool'
directory.
4. When the ChipTool program is running, the program shows a list containing at least one
entry describing the actual network parameters of the sat-nms ACU19V.
5. The serial number of the core module shown in the first column of the list. If the list stays
empty, the ACU is not connected properly. If there are more entries in the list, the
configuration program has found other devices in this network segment which use the same
technology.
6. Now open with a right-click the sub-menu 'IP configuration' to open the IP configuration
window of the program. In this form the ACU's MAC address is shown on top, below you find
the fields to configure the new IP address and network mask. If the ACU later shall be
operated through a router, enter the address of the router on the gateway field, otherwise
leave this field blank. Be sure, that the 'DHCP' mark is unchecked, the other values have to
be set as shown on the picture. Finally click to the 'Yes' button to set the new parameters at
the ACU.
Now the IP configuration of the ACU is completed. You may finally want to test if the ACU is
reachable now. Start your web browser and type the ACU's IP address into the URL field of the
browser. The ACU should reply with it's main page, provided that the ACU and your computer are
configured for the same subnet.
(C) 2022, SatService GmbH
www.satnms.com