Rooftop Mounting; Ground Level - Nordyne Q6SP-090 Series Installation Instructions Manual

Single package electric heat pump rooftop unit
Table of Contents

Advertisement

Figure 3
Figure 3. Side View
Figure 4
Crate Brackets (x4)
Base
Rails
Long Bottom
Boards (x2)
Figure 4. Bottom View
Figure 5
LIFTING
BEAM
SPREADER
BAR
Figure 5. Rigging & Hoisting
Wood Cap
Assembly
Top Crate
Brackets
End Skid
Lower
Crate
Brackets
Short Bottom
Boards (x2)
CABLE OR CHAIN
SPREADER
BAR
Units may be installed on wood flooring or on Class A, B,
or C roof covering material when used with side supply
and return air ducts. (Horizontal Discharge Kit required.)
Units may be installed on wood flooring or on Class A,
B, or C roof covering material when used with bottom
discharge and return air ducts in conjunction with a roof
curb. If installing units on a combustible floor with
downflow discharge, a roof curb is required.
Units may be installed on non- combustible flooring when
used with bottom supply and return air ducts.

Rooftop Mounting

For rooftop installations use the appropriate accessory
roof curb and follow all instructions included with it. See
Figure 6 (page
6). Locate the unit according to local
building codes and ordinances. The roof curb must be
square and level to ensure proper condensate drainage
and unit operation.
• On bottom discharge applications, supply and return air
ducts must be attached to the roof curb duct supports,
not the unit. Install all ductwork before setting unit to
curb or frame. NOTE: In downflow applications never
drill or punch holes in unit base. Leakage may occur if
unit bottom pan is punctured.
• If any brand other than a NORDYNE Roof Curb is to
be used the frame support must be constructed using
non-combustible materials.
• Units require full perimeter support under the unit.
Supports must be made of steel or suitably treated
wood materials. The unit must be square and level to
ensure proper condensate drainage.
• The roof must be capable of handling the weight of the
unit. Reinforce the roof if required. See
16)
for unit weights.
• Frame must be high enough to ensure prevention of
any moisture from entering the unit. Recommended
height to unit base is 8" (20cm) for both Downflow and
Horizontal applications.
• Secure roof curb or frame to roof using acceptable
mechanical methods per local codes.

Ground Level

WARNING:
Do not place combustible material on or against
the unit cabinet. Do not place combustible
materials, including gasoline and any other
flammable vapors and liquids, in the vicinity of
the unit.
If installing the unit at ground level, provide a concrete
mounting pad separate from the building foundation. The
pad must be level to ensure proper condensate disposal
and strong enough to support the unit's weight. Make sure
the slab is a minimum of 3" (8cm) above grade and in an
area that drains well. See
Ductwork should be attached directly to flanges on panels
supplied in horizontal duct conversion kits. Unit Base Rails
provide full perimeter support under the unit. The unit
Table 1, (page
Figure 7 (page
6).
5