Gewiss Chorus GW 10 794H Programming Manual

Gewiss Chorus GW 10 794H Programming Manual

Timed thermostat / programmer t+h knx - flush-mounting

Advertisement

Quick Links

Cronotermostato/Programmatore T+H KNX - da incasso
Timed thermostat / Programmer T+H KNX - flush-mounting
Thermostat programmable / Programmateur T+H KNX - à encastrer
Cronotermostato/Programador T+H KNX - de empotrar
Chronothermostat/Programmierer T+H KNX - für den Unterputz
GW 10 794H
GW 12 794H
GW 14 794H
MANUALE DI PROGRAMMAZIONE
PROGRAMMING MANUAL - MANUEL DE PROGRAMMATION
MANUAL DE PROGRAMACIÓN - PROGRAMMIERHANDBUCH

Advertisement

Table of Contents
loading

Summary of Contents for Gewiss Chorus GW 10 794H

  • Page 1 Cronotermostato/Programmatore T+H KNX - da incasso Timed thermostat / Programmer T+H KNX - flush-mounting Thermostat programmable / Programmateur T+H KNX - à encastrer Cronotermostato/Programador T+H KNX - de empotrar Chronothermostat/Programmierer T+H KNX - für den Unterputz GW 10 794H GW 12 794H GW 14 794H MANUALE DI PROGRAMMAZIONE PROGRAMMING MANUAL - MANUEL DE PROGRAMMATION...
  • Page 3: Table Of Contents

    CONTENTS page GENERAL DESCRIPTION Briefly .............4 Position of the commands .
  • Page 4: General Description

    All the information concerning the technical data of the product, the connection diagrams, the descriptions of the commands, and the instructions for correct assembly are contained in the installation manual supplied with the product and which can also be downloaded from the website www.gewiss.com.
  • Page 5: Position Of The Commands

    GENERAL DESCRIPTION Position of the commands The timed thermostat is equipped with a backlit LCD display and four command push- buttons that can always be accessed. ATTENTION! If the display backlighting is enabled, only the screen will light up when any one of the 4 front button keys is pressed for the first time;...
  • Page 6 GENERAL DESCRIPTION INFORMATION ON THE DISPLAY Symbol Time of day / Variable value of the hourly profile / Value shown on the humidity page (Hr = relative humidity; HA = specific humidity; tr = dew point temperature) Day of the week Programming mode Settings menu Battery charge level...
  • Page 7: Control Modes

    GENERAL DESCRIPTION Control modes The timed thermostat can be set with 2 different control modes: • Master: the timed thermostat sets the type, operating mode or setpoint of the devices configured as slaves (e.g. the KNX flush-mounting thermostats GW1x795H), on the basis of the ETS parameterisation.
  • Page 8: Operating Mode

    GENERAL DESCRIPTION MEANING OF Heating Cooling Symbol Operating Operating Setpoint Setpoint mode mode Economy Comfort ECONOMY COMFORT Pre-comfort Pre-comfort COMFORT COMFORT Comfort Economy COMFORT ECONOMY The anti-freeze function is only active in heating mode, when the temperature adjustment system is switched OFF. In this case, the timed thermostat uses the fixed anti-freeze temperature setpoint, only reactivating the heating system if the room temperature falls below T...
  • Page 9 GENERAL DESCRIPTION During operation, the activation of the heating or cooling mode is indicated in the following way: Heating symbol indicates that the activation command has been sent to the command actuator of the boiler or area solenoid valve (1st stage of the heating system ).
  • Page 10: User Instructions

    USER INSTRUCTIONS Timed thermostat operation statuses The timed thermostat has three distinct operation statuses: - Normal operation - Parameter setting - Hourly profile programming When it is switched on, the timed thermostat goes into “normal operation” status. Using the button key, you can switch from one status to another (the switchover from “parameter setting”...
  • Page 11 USER INSTRUCTIONS Forcing the setpoint manually If the displayed page relates to the timed thermostat and any HVAC mode other than OFF is active, press the button key to temporarily modify the setpoint of the active HVAC mode, then confirm with the button key or wait for the 5-second time-out period to elapse.
  • Page 12 USER INSTRUCTIONS To deactivate the Party function in advance, press the button key and keep it pressed until the unit has returned to normal operation. Holiday function In the Auto, Economy, Pre-comfort and Comfort modes, the Holiday function allows you to temporarily exclude the set operating mode and activate the Economy mode with an adjustable setpoint, for a period of time between 1 and 99 days.
  • Page 13 USER INSTRUCTIONS Copying the holiday program In Auto mode, you can copy the profile of the holiday day onto any day of the week. This function can be activated up to 6 days ahead of the chosen day. It is especially useful when a holiday day falls during the week.
  • Page 14 USER INSTRUCTIONS Pages relating to the humidity section View the humidity parameters If the page displayed relates to the humidity section, press the button key to view the relative humidity value Hr, specific humidity HA and dew point temperature tr. To return to the screen listing the pages that can be viewed, keep the button key pressed.
  • Page 15 USER INSTRUCTIONS General parameters Setting the day Access to the Set menu is indicated by the word SET on the display, and by the flashing of the day of the week. Set the day by means of the button keys (MON, TUE, WED, THU, FRI, SAT, SUN).
  • Page 16 USER INSTRUCTIONS Returning to the main page Use the button key to set the main page that the device must automatically visualise at the end of a period of inactivity by the user (OFF = function disabled; TIMED THERMOSTAT = main page of the timed thermostat; PRO01, PRO02 ...
  • Page 17 USER INSTRUCTIONS Single-colour theme for icon colour Use the button key to modify the colour of the icons within a single-colour theme. This parameter is only visible if the icon theme is single-colour and the back-lighting is active. To confirm your choice and move on to the next parameter, press the button key within 30 seconds.
  • Page 18 USER INSTRUCTIONS Operating parameters White balancing Use the button keys to set the weight of the red (RED), green (GRE) and blue (BLU) component in the backlighting of the display (value can be set between 1 and 63). The regulation only applies to the white colour of the screen.
  • Page 19 USER INSTRUCTIONS If the displayed page relates to the timed thermostat (type of operation: heating) Setpoint setting Used to modify the temperature value associated with the setpoint. Adjust the value of ) with the aid of the ECONOMY button keys. To confirm the set value and move on to the next parameter, press the button key within 30 seconds.
  • Page 20 USER INSTRUCTIONS If the displayed page relates to the timed thermostat (type of operation: cooling) Setpoint setting Used to modify the temperature value associated with the setpoint. Adjust the value of ) with the aid of the COMFORT button keys. To confirm the set value and move on to the next parameter, press the button key within 30 seconds.
  • Page 21 USER INSTRUCTIONS If the operating type is “auto”, the setpoint setting pages visualised are those relating to the operating type active in that moment (heating or cooling). ATTENTION! The setpoint values are subject to the following limitations: EATING (Tanti-freeze) ≤ ≤...
  • Page 22 USER INSTRUCTIONS Setting Used to modify Value 4 (defined in ETS) of the hourly profile associated with the status, if the control variable is other than 1 bit. Adjust the value using the button keys. To confirm the set value and move on to the next parameter, press the button key within 30 seconds.
  • Page 23 USER INSTRUCTIONS Humidity thresholds (from 1..5) Use the button keys to modify the value of the relative humidity thresholds (up to 5, if enabled in ETS). The gap that can be set varies from 1% to 100%. To confirm the set value and move on to the next parameter, press the button key within 30 seconds.
  • Page 24 USER INSTRUCTIONS TWO POINTS ON-OFF The operating principle manages the temperature adjustment system with two thresholds (hysteresis cycle), used to distinguish the ON or OFF status of the system. In heating mode, when the detected temperature is lower than the “setpoint - ”...
  • Page 25 USER INSTRUCTIONS TWO POINTS 0%-100% The operating principle is similar to that of the two points ON-OFF, but with the difference that the communication objects for temperature adjustment management are of 1 byte. In heating mode, when the detected temperature is lower than the “setpoint - ”...
  • Page 26 USER INSTRUCTIONS Activating the self-learning function (heating mode only) The self-learning function allows you to optimise the heating activation advance (max. 2 hours). The timed thermostat manages the advance automatically so as to guarantee the set temperature at the start of each programmed profile period. This function can only be activated in heating mode, in automatic operation.
  • Page 27 USER INSTRUCTIONS The device keeps the temperature adjustment system switched on for a cycle time percentage that depends on the output function of the proportional-integral control; the device continually adjusts the system, modulating the system ON-OFF times with a duty- cycle that depends on the value of the output function (calculated at each time gap equal to the cycle time).
  • Page 28 USER INSTRUCTIONS function: the proportional component and the integral component, used to improve the response in order to reach the temperature at the fixed setpoint. Once the proportional band has been defined (from setpoint to setpoint - for heating mode, from setpoint to setpoint for cooling mode), its width determines the extent of the system response: if it is too narrow, the system will be more reactive but with swings;...
  • Page 29 USER INSTRUCTIONS FAN COIL WITH ON-OFF SPEED CONTROL The operating principle involves activating/deactivating the fan coil speeds on the basis of the difference between the fixed setpoint and the detected temperature, using independent 1-bit communication objects to manage the individual speeds. The figures below refer to the control of the speeds of a fan coil with three operating stages for heating and cooling.
  • Page 30 USER INSTRUCTIONS Speed V1 is activated when the temperature value is lower than the “setpoint - valve ” value (in heating mode) or higher than the “setpoint + ” value 1heat valve 1cond (in cooling mode), and deactivated when the temperature value reaches the “setpoint - ”...
  • Page 31 USER INSTRUCTIONS FAN COIL WITH CONTINUOUS SPEED CONTROL The operating principle is similar to that of the fan coil with ON-OFF speed control, but with the difference that there are no independent communication objects for managing the individual speeds - just one 1-byte object. The figures below refer to the control of the speeds of a fan coil with three operating stages for heating and cooling.
  • Page 32 USER INSTRUCTIONS Speed V1 is activated when the temperature value is lower than the “setpoint - valve ” value (in heating mode) or higher than the “setpoint + ” value 1heat valve 1cond (in cooling mode), and deactivated (sending of “fan OFF” value) when the temperature value reaches the “setpoint - ”...
  • Page 33 USER INSTRUCTIONS Setting the valve adjustment differential Use the button keys to set the value of the adjustment differential of the fan coil valve control algorithm (the gap can be set from 0.1°C to 2.0°C). If the control logic is common, the parameter remains the same in both heating and cooling mode.
  • Page 34 USER INSTRUCTIONS Setting the inertia for speed 3 Use the button key to set the value of the inertia time for fan coil speed 3 (the gap can be set from 0 to 10 seconds). This parameter is visible if the fan coil speed number is 3.
  • Page 35: Hourly Profile Programming

    USER INSTRUCTIONS Hourly profile programming To personalise the hourly profile program of the device, call up the main page of the timed thermostat or the general hourly timer profile then press the button key twice. You will see the word PROG on the screen. To quit the programming procedure without saving any modifications made to the current page, just press the button key again or wait 30 seconds from the last pressure on the button keys.
  • Page 36 USER INSTRUCTIONS NB: if the hourly timer output object has a dimension of 1 bit, 3 values can be set: - no action = no spots; - action associated with value 0 = 1 spot; - action associated with value 1 = 3 spots. Completing the customisation After repeating the above steps to obtain the required hourly profile, you can: - copy the program onto the next day and confirm the programming by pressing the...
  • Page 37: Pre-Set Programs

    USER INSTRUCTIONS Pre-set programs The timed thermostat has 2 pre-set programs, one for heating and the other for cooling. HEATING PROGRAM Monday - Friday Saturday - Sunday COOLING PROGRAM Every day of the week These pre-set programs can be modified and customised according to your own particular needs.
  • Page 38 USER INSTRUCTIONS Day of the week Monday Time 0.00 16 °C 18 °C Heating temperature setpoint 20 °C 5 °C ANTI FREEZE 24 °C 26 °C Cooling temperature setpoint 28 °C 35 °C HIGH TEMPERATURE PROTECTION Temperature measurement unit °C common, Control logic 2 ON-OFF points...
  • Page 39 USER INSTRUCTIONS F.A.Q. What does the temperature value on the display actually represent? If no external temperature probe is enabled during ETS programming, the value shown on the display is the temperature detected by the sensor in the timed thermostat. If, however, an external temperature probe (of the KNX or NTC type) has been enabled, the timed thermostat shows the average of the values detected by the probe and the sensor, using a variable weight between 10% and 100% (which can be defined via ETS).
  • Page 40 According to article 9 paragraph 2 of the European Directive 2004/108/EC, the responsible for placing the apparatus on the Community market is: GEWISS S.p.A Via A. Volta, 1 - 24069 Cenate Sotto (BG) Italy Tel: +39 035 946 111 Fax: +39 035 945 270 E-mail: qualitymarks@gewiss.com +39 035 946 111 sat@gewiss.com...