Gewiss Chorus GW 10 764 Programming Manual

Gewiss Chorus GW 10 764 Programming Manual

Easy timed thermostat flush-mounting

Advertisement

Quick Links

Cronotermostato Easy - da incasso
Easy timed thermostat - flush-mounting
Thermostat programmable Easy - à encastrer
Cronotermostato Easy - de empotrar
Easy-Chronothermostat - für den Unterputz
GW 10 764
GW 12 764
GW 14 764
MANUALE DI PROGRAMMAZIONE
PROGRAMMING MANUAL - MANUEL DE PROGRAMMATION
MANUAL DE PROGRAMACIÓN - PROGRAMMIERHANDBUCH

Advertisement

Table of Contents
loading

Summary of Contents for Gewiss Chorus GW 10 764

  • Page 1 Cronotermostato Easy - da incasso Easy timed thermostat - flush-mounting Thermostat programmable Easy - à encastrer Cronotermostato Easy - de empotrar Easy-Chronothermostat - für den Unterputz GW 10 764 GW 12 764 GW 14 764 MANUALE DI PROGRAMMAZIONE PROGRAMMING MANUAL - MANUEL DE PROGRAMMATION MANUAL DE PROGRAMACIÓN - PROGRAMMIERHANDBUCH...
  • Page 3: Table Of Contents

    CONTENTS page GENERAL DESCRIPTION Briefly .............4 Position of the commands .
  • Page 4: General Description

    More information about procedure for programming the timed thermostat with the Easy configurator can be found in the Programming Manual of the Easy devices with the Easy Controller (can be downloaded from www.gewiss.com).
  • Page 5: Position Of The Commands

    GENERAL DESCRIPTION Position of the commands The timed thermostat is equipped with a backlit LCD display and four command push- buttons that can always be accessed. Description of the commands COMMAND PUSH-BUTTONS Symbol Select operating mode / Confirm Adjust temperature (+) / Visualise pages Adjust temperature (-) / Visualise pages Set parameters / Program profiles...
  • Page 6 GENERAL DESCRIPTION INFORMATION ON THE DISPLAY Symbol Time / Variable value of hourly profile / Hourly profile of input temperature Day of the week Programming mode Settings menu Battery charge level Heating activation Air-conditioning activation Type of operation: heating Type of operation: air-conditioning Party function Holiday function Non-workday program...
  • Page 7: Control Modes

    GENERAL DESCRIPTION Control modes The timed thermostat can be set with 2 different control modes: • Master: the timed thermostat sets the type, operating mode or set-point of the devices configured as slaves (for example the flush-mounting Easy thermostats GW1x765). In the first case (modes), the thermostats use the locally set set-points.
  • Page 8 GENERAL DESCRIPTION MEANING OF Heating Air-conditioning Symbol Operating Operating Set-point Set-point modes modes Economy Comfort ECONOMY COMFORT Pre-comfort Pre-comfort COMFORT COMFORT Comfort Economy COMFORT ECONOMY The anti-freeze function is only active in heating mode, when the temperature adjustment system is switched OFF. In this case, the timed thermostat uses the setpoint temperature set-point, only reactivating the heating system if the room temperature falls below T...
  • Page 9: Timed Thermostat Operation Statuses

    GENERAL DESCRIPTION During operation, the activation of heating or conditioning mode is indicated in the following way: Heating The symbol indicates that the activation command was sent to the actuator that controls the boiler or area solenoid valve. If the timed thermostat does not receive confirmation of effective implementation from the actuator, the symbol will start to flash.
  • Page 10: User Instructions

    USER INSTRUCTIONS Normal operation In normal operating conditions, the pages containing information about the timed thermostat are visualised. If the hourly timer function was enabled during ETS programming, the relative pages will also be shown. Choosing the page you want to see To access the screen listing the pages that can be viewed (relating to the timed thermostat and the hourly timer), press the button key and keep it pressed until the...
  • Page 11 USER INSTRUCTIONS Choosing the fan coil speed If the visible page relates to the timed thermostat and any HVAC mode other than OFF is active, press simultaneously to access the selection page (the control algorithm of the heating/conditioning function must be set on "fan coil" from the ETS).
  • Page 12 USER INSTRUCTIONS Holiday function In the Auto, Economy, Pre-comfort and Comfort modes, the Holiday function allows you to temporarily exclude the set operating mode and activate the Economy mode with an adjustable set-point, for a period of time of 1 - 99 days. This function can be used, for instance, to set the economic operation of the temperature adjustment system during a holiday or a long period of absence, being sure of having the...
  • Page 13 USER INSTRUCTIONS Copying the holiday program In Auto mode, you can copy the profile of the holiday day onto any day of the week. This function can be activated up to 6 days ahead of the chosen day. It is especially useful when a holiday day falls during the week.
  • Page 14: Parameter Setting

    USER INSTRUCTIONS Parameter setting To set the operating parameters of the device, bring up the main timed thermostat page or the general hourly timer profile on the screen, then press the button key. To quit the parameter setting procedure without saving the modifications made on the current page, just press the button key again or wait 30 seconds from the last pressure on the button keys.
  • Page 15 USER INSTRUCTIONS Setting the temperature measurement unit When the °C or °F temperature symbol begins flashing, select the temperature measurement unit by means of the button keys. To confirm your choice and move on to the next parameter, press the button key within 30 seconds.
  • Page 16 USER INSTRUCTIONS Back-lighting timing Use the button key to set the minimum duration of the inactivity time of the user before the back-lighting is automatically deactivated (the gap can be set from 10 to 180 seconds). This parameter is only visible if the back-lighting is active. To confirm your choice and move on to the next parameter, press the button key within 30 seconds.
  • Page 17 USER INSTRUCTIONS Alarm threshold temperature setting Use the button key to set the floor temperature limit above which the timed thermostat blocks heating to prevent any damage (value expressed in tenths of a °C, can be set between 150 and 1000, with steps of 100).
  • Page 18 USER INSTRUCTIONS Setting the set-point (heating) / Used to modify the temperature value associated with the set-point (if the page visualised relates to the timed thermostat), or the Value 2 of the hourly profile associated with the status (if the page visualised relates to the hourly timer).
  • Page 19 USER INSTRUCTIONS If the operating type is "air-conditioning": Setting the set-point (air-conditioning) / Used to modify the temperature value associated with the set-point (if the page visualised relates to the timed thermostat), or the Value 1 of the hourly profile associated with the status (if the page visualised relates to the hourly timer).
  • Page 20 USER INSTRUCTIONS Setting the high temperature protection value / Used to modify the temperature value associated with the set-point (if the page visualised relates to the timed thermostat), or the Value 4 of the hourly profile associated with the status (if the page visualised relates to the hourly timer).
  • Page 21 USER INSTRUCTIONS Temperature adjustment control algorithm Use the button key to change the control algorithm for heating , air conditioning or both (2P = two points On/Off; PI = PWM proportional-integral; FAN = fan coil with speed control On/Off) based on the type of operation and the control logic set in the previous screens.
  • Page 22 USER INSTRUCTIONS Setting the adjustment differential Use the button keys to set the value of the adjustment differential of the two-point control algorithm (the gap can be set from 0,1°C to 2,0°C). To confirm your choice and move on to the next parameter, press the button key within 30 seconds.
  • Page 23 USER INSTRUCTIONS PWM PROPORTIONAL-INTEGRAL The PWM control algorithm, used to control the temperature adjustment system, allows you to drastically reduce the times subject to thermal inertia and introduced by the two- point control. This type of control involves the modulation of the impulse duty-cycle, represented by the temperature adjustment system activation time, on the basis of the difference between the fixed set-point and the temperature effectively detected.
  • Page 24 USER INSTRUCTIONS The device keeps the temperature adjustment system switched on for a cycle time percentage that depends on the output function of the proportional-integral control; the device continually adjusts the system, modulating the system ON-OFF times with a duty- cycle that depends on the value of the output function (calculated at each time gap equal to the cycle time).
  • Page 25 USER INSTRUCTIONS FAN COIL WITH ON-OFF SPEED CONTROL The operating principle involves activating/deactivating the fan coil speeds on the basis of the difference between the fixed set-point and the detected temperature, using independent 1-bit communication objects to manage the individual speeds. The figures below refer to the control of the speeds of a fan coil with three operating stages for heating and air-conditioning.
  • Page 26 USER INSTRUCTIONS Speed V1 is activated when the temperature value is lower than the “set-point - valve ” value (in heating mode) or higher than the “set-point + ” value 1heat valve 1cond (in air-conditioning mode), and deactivated when the temperature value reaches the “set- point - ”...
  • Page 27 USER INSTRUCTIONS Setting the speed adjustment differential 1 Use the button key to set the value of the adjustment differential for the fan coil speed 1 (the gap can be set from 0°C to 2,0°C). If a value of 0°C is set, then when the solenoid valve is activated fan coil speed 1 will be instantaneously activated as well.
  • Page 28: Hourly Profile Programming

    USER INSTRUCTIONS Hourly profile programming To customise the device's hourly profile program, call up the main page of the timed thermostat or the general hourly timer profile (check that the profiles were enabled with the Easy controller) then press the button key twice until the word PROG appears on the screen.
  • Page 29: Operation With Battery

    USER INSTRUCTIONS Completing the customisation After repeating the above steps to obtain the required hourly profile, you can: - copy the program onto the next day and confirm the programming by pressing the button keys simultaneously within 30 seconds, or - confirm the programming without copying it, by pressing the button key within 30 seconds and keeping it pressed (you will move on automatically to the programming of the next day).
  • Page 30 USER INSTRUCTIONS Easy channel localisation mode To access the Easy channel localisation mode, start from the normal timed thermostat operating screen and press the button key three times. In this way the channels implemented by the device can be localised to insert them in the various functions implemented with the Easy configurator (Easy Controller).
  • Page 31 USER INSTRUCTIONS SLA (Slave) To be used to set: • remotely, with other Easy devices, the type (heating/air conditioning) and the HVAC operating mode of the timed thermostat. Examples of devices that can be used include the Easy GSM remote control, the Easy command and display panel, the Easy channel interface 4, etc;...
  • Page 32 USER INSTRUCTIONS HS1 (Speed 1 heating fan coil) To be used to send the On/Off command to the Easy actuator channel that controls the speed 1 of the heating fan coil. HS2 (Speed 2 heating fan coil) To be used to send the On/Off command to the Easy actuator channel that controls the speed 2 of the heating fan coil.
  • Page 33: Pre-Set Programs

    USER INSTRUCTIONS Pre-set programs The timed thermostat has 2 pre-set programs, one for heating and the other for air- conditioning. HEATING PROGRAM Monday - Friday Saturday - Sunday AIR-CONDITIONING PROGRAM Every day of the week These pre-set programs can be modified and customised according to your own particular needs.
  • Page 34 USER INSTRUCTIONS Day of the week Monday Time 0.00 16 °C 18 °C Heating temperature set-point 20 °C 5 °C ANTI FREEZE 24 °C 26 °C Air-conditioning temperature set-point 28 °C 35 °C HIGH TEMPERATURE PROTECTION Temperature measurement unit °C common, Control logic 2 points ON-OFF...
  • Page 35 USER INSTRUCTIONS F.A.Q. What does the temperature value on the display actually represent? If no external temperature probe is enabled during programming, the value on the display corresponds to the temperature detected by the sensor built into the timed thermostat. If, however, an external temperature probe (of the Easy or NTC type) has been enabled, the timed thermostat shows the average between the values detected by the probe and the sensor, using a variable weight between 10% and 100% (which can be defined via the Easy...
  • Page 36 According to article 9 paragraph 2 of the European Directive 2004/108/EC, the responsible for placing the apparatus on the Community market is: GEWISS S.p.A Via A. Volta, 1 - 24069 Cenate Sotto (BG) Italy Tel: +39 035 946 111 Fax: +39 035 945 270 E-mail: qualitymarks@gewiss.com +39 035 946 111 sat@gewiss.com...