Ascon tecnologic X30 Operating Instructions Manual

Ascon tecnologic X30 Operating Instructions Manual

Digital electronic controller for refrigeration units and data acquisition and transmission module on rs485 network
Table of Contents

Advertisement

Quick Links

X30
DIGITAL ELECTRONIC
CONTROLLER FOR
REFRIGERATION UNITS AND DATA
ACQUISITION AND TRANSMISSION
MODULE ON RS485 NETWORK
OPERATING INSTRUCTIONS
17/12 - Code:ISTR_M_X30-_E_01_--
ASCON TECNOLOGIC S.r.l.
Viale Indipendenza 56, 27029 - VIGEVANO (PV) ITALY
Tel.: +39 0381 69871 - Fax: +39 0381 698730
http:\\www.ascontecnologic.com
info@ascontecnologic.com
PREFACE
This manual contains the information necessary for
m
the product to be installed correctly and also instruc-
tions for its maintenance and use; we therefore recom-
mend that the utmost attention is paid to the following
instructions and to save it.
This document is the exclusive property of Ascon Tecnologic
S.r.l. which forbids any reproduction and divulgation, even
partially, of the document, unless expressly authorized.
Ascon Tecnologic S.r.l. reserves the right to make any formal
or functional changes at any moment and without any notice.
Ascon Tecnologic S.r.l. and its legal representatives do not
assume any responsibility for any damage to people, things
or animals deriving from violation, wrong or improper use or
in any case not in compliance with the instrument features.
Whenever a failure or a malfunction of the device
m
may cause dangerous situations for persons, thing
or animals, please remember that the plant has to be
equipped with additional electromechanical devices
which will guarantee safety.
Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 1
Index
1. Instrument description ............................................... 2
1.1
General description ........................................................... 2
1.2
Instrument description ...................................................... 2
2. Programming ............................................................... 2
3. Usage warnings ........................................................... 2
3.1
Admitted use ..................................................................... 2
4. Installation warnings ................................................... 2
4.1
Mechanical mounting ........................................................ 2
4.1.1
Dimensions [mm] .................................................................. 3
4.2
Electrical connections ....................................................... 3
4.2.1
Electrical wiring diagram ....................................................... 3
5. Functions ..................................................................... 3
5.1
ON/Stand-by function ........................................................ 3
5.2
5.2.1
Normal-Eco mode operation ................................................. 3
5.2.2
Turbo - Normal - Eco mode operation ................................. 4
5.3
Measuring and display ...................................................... 4
5.4
Digital inputs ..................................................................... 5
5.5
Outputs and buzzer configuration ..................................... 6
5.6
Temperature control .......................................................... 7
5.7
5.8
Defrost control ................................................................... 8
5.8.1
Starting automatic defrosts ................................................... 8
5.8.2
Manual defrost ...................................................................... 9
5.8.3
End of defrosts ..................................................................... 9
5.8.4
5.8.5
Defrost display lock ............................................................. 11
5.8.6
Hot-gas defrost in centralized systems ............................... 11
5.9
Evaporator fans control ................................................... 12
5.10 Alarm functions ............................................................... 12
5.10.1 Temperature alarms ............................................................ 13
5.10.2 External alarms (digital inputs) ........................................... 13
5.10.3 Open door alarm................................................................. 13
5.11 HACCP function (alarm recording) ................................. 13
5.11.1 HACCP temperature alarms ............................................... 14
5.11.2 HACCP power failure (black-out) alarms ............................ 14
5.11.3 HACCP alarms from digital inputs ...................................... 15
occur at defined times ..................................................... 15
5.14 RS485 Serial Intefarce .................................................... 16
6. Accessories ............................................................... 16
6.1
6.2
TVR Y remote display ..................................................... 16
7. Communications protocol ........................................ 17
7.1
programmable parameter table ....................................... 17
7.1.1
Variables zones .................................................................. 17
7.1.2
Command zone .................................................................. 19
7.1.3
7.1.4
7.1.5
Data zone related to the calendar clock ............................. 24
7.1.6
Data zone related to stored HACCP alarms ....................... 24
8. Problems, maintenance and warranty ..................... 27
8.1
Notifications .................................................................... 27
8.1.1
Error messages .................................................................. 27
8.1.2
Other messages ................................................................. 27
8.2
Cleaning .......................................................................... 27
8.3
Warranty and Repairs ..................................................... 27
8.4
Disposal .......................................................................... 27
9. Technical data ............................................................ 27
9.1
Electrical characteristics ................................................. 27
9.2
Mechanical characteristics .............................................. 27
9.3
Functional features ......................................................... 28
10. How to order .............................................................. 28
/Aux .................................. 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ascon tecnologic X30

  • Page 1: Table Of Contents

    Mechanical characteristics ..........27 equipped with additional electromechanical devices Functional features ............28 10. How to order .............. 28 which will guarantee safety. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 1...
  • Page 2: Instrument Description

    TTL communications port: This port can be used to duction of conductive substances into the instrument. connect: Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 2...
  • Page 3: Dimensions [Mm]

    – When the door is opened if the SPE Set Point is active that may cause irregularities in the plant that could from parameter i. E t (switching from Eco to Normal); cause damage to people, things or animals. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 3...
  • Page 4: Turbo - Normal - Eco Mode Operation

    Normal mode. the evaporator fans (see relative functions); Turbo mode can be applied manually, for example when the Auxiliary Probe: can be used as a display-only probe Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 4...
  • Page 5: Digital Inputs

    HACCP alarms. the parameter d. d L (see the defrost function). 11 Reset of HACCP alarms: closing the input deletes all recorded HACCP alarms. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 5...
  • Page 6: Outputs And Buzzer Configuration

    Output ON when the instrument is ON. The output is not active (OFF) when the instrument is in OFF or Stand-by cndition. This mode can be used to control lights, non- misting resistance on room door or other utilities. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 6...
  • Page 7: Temperature Control

    E d or r. H d and the intrument automatically assumes it has positive values (when Cool- ing) whereas for the output HE the differential will be r. H D with values assumed to be negative (when Heating). Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 7...
  • Page 8: Defrost Control

    (i.e. at each deactivation of the output the output dF during defrosting must always remain active). ot) or however at defrost interval end with counts the total function time (instrument ON). Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 8...
  • Page 9: Manual Defrost

    EP evaporator probe value, to the differential r. d , the start of a continuous cycle exceeds the temperature set in the parameter d. t E. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 9...
  • Page 10: Defrosts In Event Of Evaporator Probe Error

    E (for output dF which controls evapora- value even if the probe configured as 2P is in error). tor 1 defroster) and d. d 2 (for output 2d which manages the evaporator 2 defroster). Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 10...
  • Page 11: Defrost Display Lock

    (non-return valves etc.) because they are not controlled by the instrument but are still necessary for the correct system operation. To avoid sudden pressure changes in the plant, the defrost Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 11...
  • Page 12: Evaporator Fans Control

    F. t n, F. t F and F. F E, are also -n Function is similar to An but with inverse logic function conditioned by a temperature control. (output active in normal conditions, disabled in alarm). Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 12...
  • Page 13: Temperature Alarms

    The function is available only for those instruments that have the calendar clock. The parameters associated with displaying HACCP alarms are contained in the ] HA group, while those associated with Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 13...
  • Page 14: Haccp Temperature Alarms

    (for alarms H2 and L2) it is possible to enable recording of out alarm recording; temperature alarms as HACCP alarms. Return of power supply (alarm end). The same parameters can also be used to define the mini- Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 14...
  • Page 15: Haccp Alarms From Digital Inputs

    HACCP Alarm Recording Disabled - Pressing the key for at least 1 s disables/enables recording of stored HACCP – No switches on Sundays. alarms. After the selection is made the display shows for Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 15...
  • Page 16: Rs485 Serial Intefarce

    The software protocol adopted for X30 is a MODBUS RTU To use the A01 device it is necessary that the device or instru- type, widely used in several PLC and supervision programs ment are being correctly supplied.
  • Page 17: Communications Protocol

    OFF; Evaporator fans ouput OFF; Aux Output OFF; Acknowledgeable alarm output OFF; Not acknowledgeable alarm output OFF; HE Heating Output OFF; Temperature controller request (uninhibited) OFF; Fans Output request (uninhibited) Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 17...
  • Page 18 1 = Open door alarm (oP); 1 = HACCP alarm in progress or not acknowledged; b5 ÷ b15 Not used. OFF; Disable HACCP alarm recording OFF; Eco mode in progress OFF; Turbo mode in progress Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 18...
  • Page 19: Command Zone

    C1 °C with resolution 0.1°; C1 = 2; F1 °F with resolution 0.1°. F1 = 3. 2807 Measuring filter oF ÷ 20.0 s oF = 0 i. F t Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 19...
  • Page 20 2819 Defrosting Type no = 2 ; d. d t Et Electrical heating with evaporator tempera- Et = 3; ture control; HG = 4. HG HOT-GAS defrost for centralized plants. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 20...
  • Page 21 283A oF/ 0.01 ÷ 99.59 (min.s) oF = 0 P. P 3 switching-on 283B Delay outputs at power ON oF/ 0.01 ÷ 99.59 (min.s) oF = 0 P. o d Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 21...
  • Page 22 L2 = 15. oF Disabled; Buzzer function mode (if present in the Active alarms only; 2854 oF = 0 o. b u operator panel) Key pressed only; Active alarms and Key pressed. Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 22...
  • Page 23: Zone For The Events Programmable By Clock

    Minutes Programmable Event 7 0 ÷ 59 c. 0 7 2C1A Day Programmable Event 7 0 ÷ 11 c. 0 7 2C1B Type of Programmable Event 7 1 ÷ 7 c. 0 7 Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 23...
  • Page 24: Data Zone Related To The Calendar Clock

    2E05 Stored Alarm n. 1: n. = Start Minutes 0 ÷ 59 H. 0 1 2E06 Stored Alarm n. 1: E. = duration (hours) 0 ÷ 99 H. 0 1 Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 24...
  • Page 25 H. 0 8 2E40 Stored Alarm n. 8: y.= Start Year 0 ÷ 99 H. 0 8 2E41 Stored Alarm n. 8: M.= Start Month 1 ÷ 12 H. 0 8 Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 25...
  • Page 26 Stored Alarm n. 10: e. = duration (minutes) 0 ÷ 59 H. 1 0 2E59 Stored Alarm n. 10: _ = peak max./min. °C/°F - 99.9 ÷ 999.0 H. 1 0 Ascon Tecnologic - X30 - OPERATING INSTRUCTIONS - PAG. 26...
  • Page 27: Problems, Maintenance And Warranty

    Operating humidity: < 95 RH% with no condensation; to our company. Storage temperature: -25 ÷ +60°C. The faulty product must be shipped to Ascon Tecnologic with a detailed description of the faults found, without any fees or charge for Ascon Tecnologic, except in the event of alternative agreements.
  • Page 28: Functional Features

    -50°C +90°C if used with NTC 103AT11 probe or Pt1000 class Clock B or better). Not present Clock Serial interface Not present RS485 - e - - h i i, j, k: RESERVED CODES; ll, mm: SPECIAL CODES. Ascon Tecnologic - Z30 - OPERATING INSTRUCTIONS - PAG. 28...

Table of Contents